PubMed Health⌕ Search

PubMed · 12030191

Pediatric management problems.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A M Alpeter, R Belkengren, S Sapala. Pediatric management problems.. https://pubmed.ncbi.nlm.nih.gov/12030191/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Electrostatic charge on spacer devices and salbutamol response in young children.

Electrostatic charge on plastic spacer devices may affect the efficacy of inhaled drugs, but its consequences have never been evaluated in asthmatic children with airflow limitation. At the end of a positive metacholine challenge, 64 children (51.3+/-12.9 months, 32 boys, specific airway resistance (SRaw) 257.1+/-56.7% and forced expiratory volume in 1s (FEV(1)) 64.2+/-17.9% of the predicted value) inhaled one puff of hydrofluoroalkane-134a (HFA-134a) salbutamol (Ventoline((R))), and 15min later two other puffs (total dose of 300 microgram), delivered through either a new static Babyhaler((R)) (n=21), a detergent-coated, reduced static, Babyhaler((R)) (n=20), or a metal NES-Spacer((R)) (n=23) equipped with facemask. SRaw and FEV(1) were measured after each treatment and compared between groups by a Kruskal-Wallis test. The first 100 microgram salbutamol induced a 151.7+/-43.9% decrease in SRaw and a 19.9+/-10.6% increase in FEV(1). Additional 200 microgram salbutamol allowed a supplementary decrease of 35.1+/-25.7% in SRaw and increase of 12.1+/-11.8% in FEV(1), without significant difference between the spacer devices. Electrostatic charge on spacer devices does not affect bronchodilation with HFA-134a salbutamol in metacholine-challenged pre-school children. This could be in part explained by the use of supramaximal doses of salbutamol.

Administration, Inhalation↗

Pharmacokinetics of ethylene in man by on-line laser photoacoustic detection.

The pharmacokinetics of ethylene are determined using laser-based photoacoustic detection and a closed chamber setup. Concentration-time data are analyzed using a two-compartment and a physiologically based pharmacokinetic (PBPK) model. Endogenous production was 92 +/- 13 pmol/h/kg for the two-compartment model and 75 +/- 10 pmol/h/kg for the PBPK model. These values agree with previous work at our department but are significantly lower than published values based on gas chromatography. The blood:air partition coefficient in the PBPK model was determined by curve fitting, because simulations based on published values did not agree well with data. Curve fitting gave a value of 0.092 +/- 0.029. The real-time nature and high sensitivity of photoacoustic detection make it a useful addition to gas chromatography in closed chamber studies.

Administration, Inhalation↗