PubMed Health⌕ Search

PubMed · 12031585

Microfluidic technologies in clinical diagnostics.

Abstract

BACKGROUND: Laboratory instrumentation and analytical devices are becoming smaller, simpler, and smarter. This trend to miniaturization extends to fluid handling and fluid analysis. However, fluid behavior undergoes significant changes as geometric scale decreases. The laminar flow behavior of fluids in microfluidic devices must be accommodated in the design and development of clinical and bio-clinical miniaturized systems. CONCLUSION: The scale of chemical and clinical analysis systems will continue to decrease. The capability to manufacture smaller fluidic devices and to quantitatively monitor smaller volumes of liquids bring this process of miniaturization into the domain of laminar flow. New and enabling technologies are being developed using the unique diffusion-based characteristics of the laminar flow domain for sample preparation and analysis. These new analytical systems will have a significant impact on the future of clinical diagnostics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Thomas H Schulte, Ron L Bardell, Bernhard H Weigl. 2002. Microfluidic technologies in clinical diagnostics.. https://doi.org/10.1016/s0009-8981(02)00093-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Robusticity and osteoarthritis at the trapeziometacarpal joint in a Bronze Age population from Tell Abraq, United Arab Emirates.

Osteoarthritis (OA) is a progressive disease of the joints and can cause pain, reduced range of motion and strength, and ultimately loss of function at affected joints. Osteoarthritis often occurs at sites where biomechanical stress is acutely severe or moderate but habitual over the course of a lifetime. Skeletal remains from an Umm an-Nar tomb at Tell Abraq, United Arab Emirates (ca. 2300 BC), were recovered and represented over 300 individuals of all ages. The remains were disarticulated, commingled, and mostly fragmented. An analysis of 650 well-preserved adult metacarpal and carpal bones, from the tomb's western chamber, revealed that over 53% of the trapeziometacarpal joint facets showed signs of OA varying from mild to severe. The first and second metacarpals and trapezium bones were sided and evaluated for OA at the trapeziometacarpal joint articulations. Osteoarthritis was detected on 53% of the first metacarpals, 40% of the second metacarpals, and 57% of the trapezium bones. All specimens appeared enlarged, and the first metacarpals were assessed for sexual identification and robusticity. Eighty-five percent of the bones were probable males, and more than 80% of them had a robusticity index of 60 or higher. A strong correlation was found between OA, sex, and robusticity. High levels of OA and robusticity at the thumb suggest that the people of Tell Abraq were habitually involved in biomechanically challenging work with their hands.

Biomechanical Phenomena↗

Paleopathological study of hallux valgus.

Hallux valgus is the abnormal lateral deviation of the great toe. The principal cause is biomechanical, specifically the habitual use of footwear which constricts the toes. In this study, descriptions of the anatomical changes of hallux valgus from published cadaveric and clinical studies were used to generate criteria for identifying the condition in ancient skeletal remains. The value of systematic scoring of hallux valgus in paleopathology is illustrated using two British skeletal series, one dating from the earlier and one from the later Medieval period. It was found that hallux valgus was restricted to later Medieval burials. This appears consistent with archaeological and historical evidence for a rise in popularity, during the late Medieval period (at least among the richer social classes), of narrow, pointed shoes which would have constricted the toes.

Biomechanical Phenomena↗

Grip force behavior during object manipulation in neurological disorders: toward an objective evaluation of manual performance deficits.

The control of prehensile finger forces is an essential feature of skilled manual performance. The basic aspects of healthy grip force behavior have been well documented. In healthy subjects, grip force is precisely adjusted to the mechanical object properties. Grip force is always slightly higher than the minimum necessary to prevent the object from slipping. When we move a hand-held object, grip force is modulated in parallel with movements-induced load fluctuations without an obvious delay. The absence of a temporal delay between grip and load force profiles suggests that the central nervous system is able to predict the load variations before the intended manipulation and consequently regulates grip force in anticipation. Feedback from the grasping fingertips is used to adjust the level of applied fingertip force efficiently to the actual loading requirements. Pathologic grip force control affects the efficiency of produced force and the precision of the temporal coupling between grip and load force profiles. Here, we review the characteristics of pathologic grip force behavior in various neurological disorders. Detailed examination of grip force control is simple and well suited for the objective evaluation of impaired motor function of the hand and its rehabilitation.

Biomechanical Phenomena↗