Debris on processed ophthalmic instruments: a cause for concern.

Abstract

PURPOSE: To assess the quality of processed ophthalmic instruments and look for the presence of foreign material on the surface of these instruments. METHODS: Data were prospectively collected on the presence of debris on processed instruments in the trays used for phacoemulsification surgery. All instruments were examined under an operating microscope before use and details of the types of debris on the various instruments were noted. If debris was found, a new tray was opened to obtain a clean instrument. RESULTS: Forty-seven trays were opened for use during the study period. Deposits on instruments were found in 29 (62%) trays. These were mainly present on the intraocular lens introducers. Loose fibres were found on instruments from eight (17%) trays. Debris was found in the aspiration channels of three (6%) hand pieces. CONCLUSIONS: A significant number of processed ophthalmic instruments had debris on their surfaces. To reduce the risk of intraocular inflammation and of transmission of prion diseases the instruments should go through a thorough decontamination process before sterilization. Routine mechanical cleaning at the end of surgery and ultrasonic cleaning before sterilization should reduce the occurrence of debris on the instruments. Instruments should also be inspected under the operating microscope before use.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S Dinakaran, V V Kayarkar. 2002. Debris on processed ophthalmic instruments: a cause for concern.. https://doi.org/10.1038/sj.eye.6700132

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Severe toxic effect of methylene blue 1% on iris epithelium and corneal endothelium.

PURPOSE: To report a case of corneal endothelial decompensation and iris pigment dispersion following the inadvertent use of methylene blue 1% for capsular staining during cataract surgery. DESIGN: Case report. METHODS: During an otherwise routine phacoemulsification cataract surgery, inadvertent anterior capsule staining with methylene blue 1% instead of trypan blue 0.025% was performed. Copious irrigation of the anterior chamber with balanced salt solution was initiated upon identification of the wrong dye. The operation was completed with minimal ultrasound energy without complications. RESULTS: Iris discoloration and severe corneal edema developed in the early postoperative period, resulting in severe visual loss. The patient developed bullous keratopathy and underwent penetrating keratoplasty 16 months later. CONCLUSIONS: In vivo intracameral injection of methylene blue 1% induces extreme cytotoxicity, primarily on the corneal endothelium and iris epithelium.

Corneal Edema↗