PubMed Health⌕ Search

PubMed · 12033491

Current developments in LC-MS for pharmaceutical analysis.

Abstract

The current developments in liquid chromatography-mass spectrometry (LC-MS) and its applications to the analysis of pharmaceuticals are reviewed. Various mass spectrometric techniques, including electrospray and nanospray ionization, atmospheric pressure chemical ionization and photoionization and their interface with liquid chromatographic techniques are described. These include high performance liquid chromatography, capillary electrophoresis and capillary electrochromatography and the advantages and disadvantages of each technique are discussed. The applications of LC-MS to the studies of in vitro and in vivo drug metabolism, identification and characterization of impurities in pharmaceuticals, analysis of chiral impurities in drug substances and high-throughput LC-MS-MS systems for applications in the "accelerated drug discovery" process are described.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Chang-Kee Lim, Gwyn Lord. 2002. Current developments in LC-MS for pharmaceutical analysis.. https://doi.org/10.1248/bpb.25.547

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Modeling the performance of pilot-scale countercurrent chromatography: scale-up predictions and experimental verification of erythromycin separation.

Biosynthesis of polyketide antibiotics, such as erythromycin A (EA), can result in the formation of analogues of the main compound that are chemically and structurally extremely similar. The large-scale purification of these antibiotics by conventional high-performance liquid chromatography (HPLC) can be prohibitively expensive due to the large volume of both solvent and adsorbent required. This study examines the feasibility of using a novel pilot-scale countercurrent chromatography (CCC) machine as an alternative to HPLC. CCC is a low-pressure (typically <4000 kN m(-2)) liquid-liquid chromatographic technique that allows the separation of solutes on the basis of their partitioning between two immiscible liquid phases. The effects of mobile phase flow rate, column rotational speed, and sample injection volume on the attainable yield and purity of EA were investigated. Our results show that, at a mobile phase flow rate of 40 mL min(-1), a rotational speed of 1200 rpm, and an injection volume of 100 mL (10 g total erythromycin), EA could be satisfactorily fractionated with a purity of approximately 92% (w/w) and a recovery yield of approximately 100% (w/w). The total solute throughput was estimated to be 0.41 kg day(-1). More importantly, we demonstrated simple and predictive linear scale-up of the CCC separation based on data obtained from a single laboratory-scale CCC chromatogram, and verified this experimentally. The retention time and peak width of the target compound at the pilot scale could be predicted to within 4% for operation at a range of mobile-phase flow rates and injection volumes. This predictable nature of CCC separations, unlike HPLC methods, can greatly reduce process development times and enable a complete process-scale operating scenario to be planned.

Chromatography, Liquid↗

Chromatographic performance of large-pore versus small-pore columns in micellar liquid chromatography.

Micellar liquid chromatography (MLC) is useful in bioanalysis because proteinaceous biofluids can be directly injected onto the column. The technique has been limited in part because of the apparently weak eluting power of micellar mobile phases. It has recently been shown [Anal. Chem. 72 (2000) 294] that this may be overcome by the use of large pore size stationary phases. In this work, large-pore (1000 A) C(18) stationary phases were evaluated relative to conventional small-pore (100 A) C(18) stationary phases for the direct sample injection of drugs in plasma. Furthermore, the difference between the large and small pore phases in gradient elution separations of mixtures of widely varying hydrophobicities was investigated. Large-pore stationary phases were found to be very effective for eluting moderately to highly hydrophobic compounds such as ibuprofen, crotamiton, propranolol, and dodecanophenone, which were highly retained on the small-pore stationary phases typically used in MLC. The advantages of direct introduction of biological samples (drugs in plasma) and rapid column re-equilibration after gradient elution in MLC were maintained with large-pore phases. Finally, recoveries, precision, linearity, and detection limits for the determination of quinidine and DPC 961 in spiked bovine plasma were somewhat better using MLC with wide pore phases.

Chromatography, Liquid↗

Highly sensitive determination of saquinavir in biological samples using liquid chromatography-tandem mass spectrometry.

A selective and sensitive method for the determination of the HIV protease inhibitor saquinavir in human plasma, saliva, and urine using liquid-liquid extraction and LC-MS-MS has been developed, validated, and applied to samples of a healthy individual. After extraction with ethyl acetate, sample extracts were chromatographed isocratically within 5 min on Kromasil RP-18. The drug was detected with tandem mass spectrometry in the selected reaction monitoring mode using an electrospray ion source and 2H(5)-saquinavir as internal standard. The limit of quantification was 0.05 ng/mL. The accuracy of the method varied between -1 and +10% (SD within-batch) and the precision ranged from +4 to +10% (SD batch-to-batch). The method is linear at least within 0.05 and 87.6 ng/mL. After a regular oral dose (600 mg) saquinavir concentrations were detectable for 48 h in plasma and were well correlated with saliva concentrations (r(2)=0.9348, mean saliva/plasma ratio 1:15.1). The method is well suited for low saquinavir concentrations in different matrices.

Chromatography, Liquid↗