PubMed Health⌕ Search

PubMed · 12074167

High-throughput array production using precision glass syringes.

Abstract

The advantages of using 1, 96, or 384 precision glass syringes in automated high-throughput microdispensers in creating highly uniform and reproducible DNA, protein, and organic compound array filters and slides are described. Using the Hydra Microdispenser and Tango Liquid Handling system, 0.1-5 ng (in 50-300 nL) PCR-amplified, human cancer-related genes and housekeeping genes were spotted onto nylon membranes and coated slides. Protein solutions of 50 microg/mL to 1 mg/mL were spotted onto coated slides or onto MaxiSorp 96-well plates. Up to 6144 spots/membrane and up to 1000 spots/slide were printed. The size of the spots created by glass syringes was uniform and reproducible (precision variation of less than 5%) from spot to spot and membrane to membrane. Using a Tango 384 system, a total of ten 6144-spot filters can be produced in approximately 25 min, translating into a spotting speed of 2.5 min/membrane.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Shieh, C To, J Carramao, N Nishimura, Y Maruta, Y Hashimoto, D Wright, H C Wu, A Azarani. 2002. High-throughput array production using precision glass syringes.. https://doi.org/10.2144/02326mt07

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Analysis of repeatability in spotted cDNA microarrays.

We report a strategy for analysis of data quality in cDNA microarrays based on the repeatability of repeatedly spotted clones. We describe how repeatability can be used to control data quality by developing adaptive filtering criteria for microarray data containing clones spotted in multiple spots. We have applied the method on five publicly available cDNA microarray data sets and one previously unpublished data set from our own laboratory. The results demonstrate the feasibility of the approach as a foundation for data filtering, and indicate a high degree of variation in data quality, both across the data sets and between arrays within data sets.

Oligonucleotide Array Sequence Analysis↗

Assessment of the relationship between signal intensities and transcript concentration for Affymetrix GeneChip arrays.

BACKGROUND: Affymetrix microarrays have become increasingly popular in gene-expression studies; however, limitations of the technology have not been well established for commercially available arrays. The hybridization signal has been shown to be proportional to actual transcript concentration for specialized arrays containing hundreds of distinct probe pairs per gene. Additionally, the technology has been described as capable of distinguishing concentration levels within a factor of 2, and of detecting transcript frequencies as low as 1 in 2,000,000. Using commercially available arrays, we assessed these representations directly through a series of 'spike-in' hybridizations involving four prokaryotic transcripts in the absence and presence of fixed eukaryotic background. The contribution of probe-target interactions to the mismatch signal was quantified under various analyte concentrations. RESULTS: A linear relationship between transcript abundance and signal was consistently observed between 1 pM and 10 pM transcripts. The signal ceased to be linear above the 10 pM level and commenced saturating around the 100 pM level. The 0.1 pM transcripts were virtually undetectable in the presence of eukaryotic background. Our measurements show that preponderance of the signal for mismatch probes derives from interactions with the target transcripts. CONCLUSIONS: Landmark studies outlining an observed linear relationship between signal and transcript concentration were carried out under highly specialized conditions and may not extend to commercially available arrays under routine operating conditions. Additionally, alternative metrics that are not based on the difference in the signal of members of a probe pair may further improve the quantitative utility of the Affymetrix GeneChip array.

Oligonucleotide Array Sequence Analysis↗