PubMed Health⌕ Search

PubMed · 12075677

The international atom: evolution of radiation control programs.

Abstract

Under the Atoms for Peace program, Turkey received a one MWt swimming pool reactor in 1962 that initiated a health physics program for the reactor and a Radiation Control Program (RCP) for the country's use of ionizing radiation. Today, over 13,000 radiation workers, concentrated in the medical field, provide improved medical care with 6,200 x-ray units, including 494 CAT scanners, 222 radioimmunoassay (RIA) labs and 42 radiotherapy centers. Industry has a large stake in the safe use of ionizing radiation with over 1,200 x-ray and gamma radiography and fluoroscopic units, 2,500 gauges in automated process control and five irradiators. A 48-person RCP staff oversees this expanded radiation use. One incident involving a spent 3.3 TBq (88 Ci) 60Co source resulted in 10 overexposures but no fatalities. Taiwan received a 1.6 MWt swimming pool reactor in 1961 and rapidly applied nuclear technology to the medical and industrial fields. Today, there are approximately 24,000 licensed radiation workers in nuclear power field, industry, medicine and academia. Four BWRs and two PWRs supply about 25% of the island's electrical power needs. One traumatic event galvanized the RCP when an undetermined amount of 60Co was accidentally incorporated into reinforcing bars, which in turn were incorporated into residential and commercial buildings. Public exposures were estimated to range up to 15 mSv (1.3 rem) per annum. There were no reported ill effects, except possibly psychological, to date. The RCP now has instituted stringent control measures to ensure radiation-free dwellings and work places. Albania's RCP is described as it evolved since 1972. Regulations were promulgated which followed the IAEA Basic Safety Standards of that era. With 525 licenses and 600 radiation workers, the problem was not in the regulations per se but in their enforcement. The IAEA helped to upgrade the RCP as the economy evolved from one that was centrally planned economy to a free market economy. As this transition takes place, public radiation exposures in the medical field will continue to be high until the old x-ray equipment is phased out. A small conscientious health physics staff works with limited resources to keep radiation exposures at acceptable levels. These three country RCPs, as they have evolved, have some commonality. Today, all radiation installations are licensed, both for radioactive material and x-ray equipment. Radiation workers are individually licensed or registered. All RCPs have, or are striving to have, their radiation regulations conform to ICRP 60 recommendations as spelled out in the Basic Safety Standard (1996). Finally, all three countries have as yet to find a permanent solution for their radioactive waste.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F J Bradley. 2002. The international atom: evolution of radiation control programs.. https://doi.org/10.1097/00004032-200207000-00015

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fermentation process tracking through enhanced spectral calibration modeling.

The FDA process analytical technology (PAT) initiative will materialize in a significant increase in the number of installations of spectroscopic instrumentation. However, to attain the greatest benefit from the data generated, there is a need for calibration procedures that extract the maximum information content. For example, in fermentation processes, the interpretation of the resulting spectra is challenging as a consequence of the large number of wavelengths recorded, the underlying correlation structure that is evident between the wavelengths and the impact of the measurement environment. Approaches to the development of calibration models have been based on the application of partial least squares (PLS) either to the full spectral signature or to a subset of wavelengths. This paper presents a new approach to calibration modeling that combines a wavelength selection procedure, spectral window selection (SWS), where windows of wavelengths are automatically selected which are subsequently used as the basis of the calibration model. However, due to the non-uniqueness of the windows selected when the algorithm is executed repeatedly, multiple models are constructed and these are then combined using stacking thereby increasing the robustness of the final calibration model. The methodology is applied to data generated during the monitoring of broth concentrations in an industrial fermentation process from on-line near-infrared (NIR) and mid-infrared (MIR) spectrometers. It is shown that the proposed calibration modeling procedure outperforms traditional calibration procedures, as well as enabling the identification of the critical regions of the spectra with regard to the fermentation process.

Calibration↗

Particle sizing with a fast polar nephelometer.

We reported previously the design of a polar nephelometer that uses a rotational confocal imaging setup to enable fast scanning of the scattering phase function within a field of view of 55 degrees . The full dynamic range of the detection system can be used by increasing the signal-to-noise ratio by means of averaging successive scans. The calibration of the angular response of the instrument is achieved by obtaining the transfer function of the optical detection system using Rayleigh scatterers. Accurate particle sizing of individual polystyrene spheres (ranging from 1.5 to 9 micro m in diameter) in aqueous suspension is achieved by maximizing a correlation coefficient between precalculated tables of Mie phase functions and data obtained from the polar nephelometer. Good correlation is achieved between experimental and theoretical data, proving the functioning of the instrument as a fast and convenient particle sizer.

Calibration↗

Online standard additions calibration of transient signals for inductively coupled plasma mass spectrometry.

An online standard additions calibration method for transient signals in ICPMS is demonstrated in which a small volume of standard is injected as a spike into the sample/carrier stream, overlaying the analyte peak. This technique provides the advantages of conventional standard additions but requires only a single sample run. The method corrects for matrix effects and is suitable for transient signals in which the severity of the matrix effect changes over the analyte peak. The method uses a peak-fitting program to determine the area of the underlying peak and is shown to be effective for the determination of trace metal concentrations in both a high ionic strength matrix and in a biological matrix (urine). Eight analytes with concentrations in the range of 0.82-233.2 mug L-1 in urine were simultaneously determined using a standard spiking solution of 75 mug L-1 injected through a 100-muL loop. The measured concentrations for analytes free of spectral interferences agreed with the certified values, and the precision achieved was comparable to that achieved by the certifying agency. Using a conventional cross-flow nebulizer and Scott-type spray chamber, the accuracy obtained for online standard additions calibration was within 2%, and the precision was within 5%.

Calibration↗