PubMed Health⌕ Search

PubMed · 12078161

[Computer assisted ENT surgery system].

Abstract

This paper describes a novel computer assisted ENT surgery system which is based on high-performanced 3D optical localizer and the combinational registration method for matching between pre-operative and intra-operative information. Preliminary results on cadaver specimen show the system is suited for clinical ENT surgery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Chen, T Zhuang, S Lavallee. 1998. [Computer assisted ENT surgery system].. https://pubmed.ncbi.nlm.nih.gov/12078161/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Noninvasive positive pressure ventilation delivered by helmet vs. standard face mask.

OBJECTIVE: This bench and human study compared large and small helmets with face mask (FM) for delivery of noninvasive positive pressure ventilation. DESIGN: A lung simulator was employed, and the human study involved six healthy subjects. We evaluated a continuous high-flow (CPAPHF), low flow (CPAPLF), ventilator (CPAPVENT) CPAP, and pressure support ventilation (PSV 10 and 20 cmH2O). In the human study we used CPAPHF, CPAPVENT, and PSV 5 cmH2O. PEEP was 5 cmH2O. MEASUREMENTS: In the bench study during CPAP we measured the negative airway pressure time product (areaCPAP), i.e., the area of airway pressure (Paw) under PEEP and during PSV the pressure airway time product (areaPSV), i.e., the area of Paw from onset to end of inspiratory flow. In the human study we measured the breathing pattern and work of breathing (WOB). RESULTS: In the bench study during CPAPLF the helmets had a lower areaCPAP than the FM, while during CPAPHF the three interfaces had similar areaCPAP. Using CPAPVENT and PSV the FM reduced areaCPAP and increased areaPSV compared to helmets. At 20 cmH2O of PSV using helmets areaPSV was similar to that obtained at 10 cmH2O of PSV using the FM. In human study using CPAPHF and CPAPVENT the tree interfaces had similar effects on breathing pattern and WOB, while using PSV the FM reduced WOB more than helmets. CONCLUSIONS: During CPAPLF helmets were more efficient than FM, while during CPAPHF the three interfaces were comparable. Using CPAPVENT and PSV, FM was more efficient than helmets

Equipment Design↗

[Suction-irrigator device for microsurgery: technical note].

A modification of the conventional suction device for microsurgery is described. It consists of a built-in tube in another tube, being the first connected to the suction device and the second to the irrigation. This suction-irrigator device allows to accomplish the suction and irrigation simultaneously and in a precise way.

Equipment Design↗

Controlling the spectral response in guided-mode resonance filter design.

Techniques for controlling spectral width are used in conjunction with thin-film techniques in the design of guided-mode resonance (GMR) filters to provide simultaneous control over line-shape symmetry, sideband levels, and spectral width. Several factors that could limit the minimum spectral width are discussed. We used interference effects for passband shaping by stacking multiple GMR filters on top of one another. A design is presented for a 200-GHz telecommunications filter along with a tolerance analysis. Compared with a conventional thin-film filter, the GMR filter has fewer layers and looser thickness tolerances. Grating fabrication tolerances are also discussed.

Equipment Design↗