PubMed Health⌕ Search

PubMed · 12078426

[Potential advantages a new syringe pump system].

Abstract

OBJECTIVES: To evaluate what could be the benefit in terms of alarm suppression, of a new syringe pumps system, which allows automatic relay without alarms. PATIENTS AND METHODS: We have prospectively recorded the nature and the mode of relay of all syringe pumps for administration of drugs to patients in two ICU. The perfusion regimen was studied in 61 patients over the complete duration of their stay in two ICU. Alarms were also recorded in one ICU room, over 13 days consecutive. The records were processed off-line with an automatic detection-recognition system in order to assess the origin of each alarm. Accordingly, the amount of alarm corresponding to monitor, ventilator and syringe pumps was computed. RESULTS: We found that syringe pumps, which would provide automatic relays without alarm, would suppress 17% of alarms in ICU and automatize 65% of the relay procedures, which are usually performed often in emergency, on response to the end of perfusion alarm. CONCLUSION: New syringe pumps allow both reduction of alarms in ICU and a better management of nurse workload. Indeed syringe relay can be planned in advance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

L Vachon, L Dubé, A M Guilleux, J P Jacob, J C Granry, L Beydon. 2002. [Potential advantages a new syringe pump system].. https://doi.org/10.1016/s0750-7658(02)00636-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tip cooling effect and failure mechanism of field-emitting carbon nanotubes.

The cooling effect accompanying field electron emission has been considered for a single carbon nanotube (CNT) used as a field emission (FE) electron source. An improved model for the failure mechanism of field emitting CNTs has been proposed and validated. Our model predicts a maximum temperature (T-max) located at an interior point rather than the tip of the CNTs, and the failure of the CNT emitters tends to take place at the T-max point, inducing a segment by segment breakdown process. A combination of Joule heating and electrostatic force effect is proposed responsible for initiating the failure of the field emitting CNT and validated by in situ FE observation.

Equipment Failure↗

[Importance of an initial check-up for diagnostic radiology apparatus management].

The management of apparatus for diagnostic imaging is an important job for radiological technologists. In the last 10 years we have encountered 2227 malfunctions in 3652 days. We detected 163 cases at the initial check-up, which accounted for 7.3% of total cases. By performing an initial check-up, we detected one malfunction every 21 days and were able to keep the effects of mishaps to a minimum, prevent accidents, and obtain stable-quality images.