PubMed Health⌕ Search

PubMed · 12083213

Mechanisms of modulation gap detection.

Abstract

It has been postulated that the central auditory system contains an array of modulation filters, each responsive to a different range of modulation frequencies present at the outputs of the (peripheral) auditory filters. In the present experiments, we tested what we call the "dip hypothesis," that a gap in modulation is detected using the "dip" in the output of the modulation filter tuned to the modulator frequency. In experiment 1, the task was to detect a gap in the sinusoidal amplitude modulation imposed on a 4-kHz carrier. The modulator preceding the gap ended with a positive-going zero-crossing. There were three conditions, differing in the phase at which the modulator started at the end of the gap; zero-phase, at a positive-going zero-crossing; pi-phase, at a negative-going zero-crossing; and "preserved" phase, at the phase the modulator would have had if it had continued without interruption. Modulation frequencies were 5, 10, 20, and 40 Hz. Psychometric functions for detection of the gap were measured using a two-alternative forced-choice task. For the zero-phase and preserved-phase conditions, the detectability index, d', increased monotonically with increasing gap duration. For the pi-phase condition, performance was good (d' > 1) for small gap durations, and initially worsened with increasing gap duration, before improving again for longer gap durations. This is the pattern of results expected from the dip hypothesis, provided that the modulation filters have Q values of 2 or more. However, it is also possible that a rhythm cue was used to improve performance in the pi-phase condition for short gap durations; the introduction of the gap markedly disrupted the regular rhythm produced by the modulator peaks. In experiment 2, the rhythm cue was disrupted by varying the modulator period randomly around its nominal value, except for the modulator periods immediately before and after the gap. This markedly impaired performance, and resulted in psychometric functions that were very similar for the zero-phase and pi-phase conditions. This pattern of results is inconsistent with the dip hypothesis. For both experiments, modulation gap "thresholds" (d' approximately 1) were roughly constant when expressed as a proportion of the modulator period. Possible mechanisms of modulation gap detection are discussed and evaluated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Aleksander Sek, Brian C J Moore. 2002. Mechanisms of modulation gap detection.. https://doi.org/10.1121/1.1474445

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A low glycaemic index breakfast cereal preferentially prevents children's cognitive performance from declining throughout the morning.

This study investigated whether the glycaemic index (GI) of breakfast cereal differentially affects children's attention and memory. Using a balanced cross-over design, on two consecutive mornings 64 children aged 6-11 years were given a high GI cereal and a low GI cereal in a counterbalanced order. They performed a series of computerised tests of attention and memory, once prior to breakfast and three times following breakfast at hourly intervals. The results indicate that children's performance declines throughout the morning and that this decline can be significantly reduced following the intake of a low GI cereal as compared with a high GI cereal on measures of accuracy of attention (M=-6.742 and -13.510, respectively, p<0.05) and secondary memory (M=-30.675 and -47.183, respectively, p<0.05).

Attention↗

Inhibitory control test is a simple method to diagnose minimal hepatic encephalopathy and predict development of overt hepatic encephalopathy.

OBJECTIVES: To compare inhibitory control test (ICT), a simple/rapid test of attention, to a standard psychometric battery (SPT) to diagnose minimal hepatic encephalopathy (MHE) and predict development of overt hepatic encephalopathy (OHE) in cirrhotic patients. METHODS: Fifty nonalcoholic cirrhotics and 50 age/educational-status-matched controls were given ICT and SPT in the same sitting. Performance impaired beyond two standard deviations of controls was considered MHE in cirrhotics. ICT results (lure/target response and lures/person) were compared between controls and cirrhotics and within cirrhotics with/without MHE. Receiver-operating characteristic analysis was used to study ICT for MHE diagnosis. Twenty subjects were administered SPT and ICT twice to assess test-retest reliability. All cirrhotics were followed routinely for the development of OHE. RESULTS: Cirrhotics performed worse than controls on SPT and ICT. Using SPT, 39 cirrhotics had MHE. ICT was administered faster than SPT (15 vs 37 min). Cirrhotics with MHE had significantly higher lure (28%vs 3%) and lower target response (91%vs 96%) compared with those without MHE. Lure/person >5 had 90% sensitivity/specificity for MHE diagnosis. AUC for receiver-operating characteristic for lures alone was 95.8%. Lure and target responses were highly correlated (r= 0.9) between sessions showing high test-retest reliability. Five (10%) patients developed OHE on f/u of 26 +/- 10 months; all five had been diagnosed with MHE using ICT and SPT. None of the five patients with discordant results on SPT and ICT developed OHE. CONCLUSIONS: ICT has good sensitivity/specificity for MHE diagnosis, is reliable and is equivalent to SPT for predicting OHE development.

Attention↗