PubMed Health⌕ Search

PubMed · 12083280

Validation studies and proficiency testing.

Abstract

Genetically modified organisms (GMOs) entered the European food market in 1996. Current legislation demands the labeling of food products if they contain <1% GMO, as assessed for each ingredient of the product. To create confidence in the testing methods and to complement enforcement requirements, there is an urgent need for internationally validated methods, which could serve as reference methods. To date, several methods have been submitted to validation trials at an international level; approaches now exist that can be used in different circumstances and for different food matrixes. Moreover, the requirement for the formal validation of methods is clearly accepted; several national and international bodies are active in organizing studies. Further validation studies, especially on the quantitative polymerase chain reaction methods, need to be performed to cover the rising demand for new extraction methods and other background matrixes, as well as for novel GMO constructs.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Elke Ankilam, Petra Heinze, Simon Kay, Guy Van den Eede, Bert Popping. Validation studies and proficiency testing.. https://pubmed.ncbi.nlm.nih.gov/12083280/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Oxygen solubilities of media used in electrochemical respiration measurements.

Solubility data are presented as equations from which the oxygen concentration of arbitrary media may be calculated with an accuracy of about 1%. These equations, covering the range 5-40 degrees C, are based on measurements with a modification of the physical method of St. Helen and Fatt (I. Fatt, Polarographic Oxygen Sensors, CRC Press, Cleveland (1976)). Solutions of the following compounds were measured: EDTA (ethylenediaminetetraacetic acid), EGTA (ethyleneglycol-bis(2-aminoethylether)tetraacetic acid), glucose, Hepes (N-2-hydroxyethylpiperazine-N'-2-ethanesulfonic acid), lactobionic acid (galactosylgluconic acid), magnesium chloride, mannitol, Mes (2-(N-morpholino)ethanesulfonic acid), potassium chloride, potassium phosphate, sodium chloride, sucrose, taurine, and Tris (tris(hydroxymethyl)aminomethane). The present data are compared with solubility data obtained with the method involving oxidation of calibrated amounts of reduced nicotinamide adenine dinucleotide (e.g., R.W. Estabrook, Methods Enzymol. 10 (1967) 41-47) and with the kinetic method of Reynafarje et al. (Anal. Biochem. 145 (1985) 406-418). It is concluded that the former method produces reliable results provided that some simple precautions are taken. The kinetic method, however, appears to have produced calibration errors up to about 5%.

Calibration↗

High-performance liquid chromatography determination of methionine adenosyltransferase activity using catechol-O-methyltransferase-coupled fluorometric detection.

A nonradioactive, sensitive, rapid, and specific method for the determination of methionine adenosyltransferase activity has been established. In this method, the methyl group of S-adenosyl-L-methionine was enzymatically transferred to esculetin with the aid of catechol-O-methyltransferase and then the resulting scopoletin was extracted with n-hexane:ethyl acetate (7:3, v/v) and measured by high-performance liquid chromatography with Si 60 column and fluorometric detection with excitation and emission wavelengths at 347 and 415 nm, respectively. The detection limit for scopoletin was about 100 fmol. Using this method to determine MAT activity in HL-60 cells required only about 2.5 microg of protein and the incubation time needed for enzymatic reaction is less than 30 min. The HPLC analysis procedure took only 5 min per sample. The kinetic study showed that MAT in HL-60 cells exhibited negative cooperativity with a Hill coefficient of 0.5. The values of K(m) and V(max) were 6.1+/-0.3 microM and 135.4+/-1.5 nmol AdoMet formed/mg protein/h, respectively.

Calibration↗