PubMed Health⌕ Search

PubMed · 12099613

Liquid-crystal adaptive optics based on feedback interferometry for high-resolution retinal imaging.

Abstract

A novel, to our knowledge, adaptive optical imaging system for high-resolution retinal imaging is described. The system is based on a feedback interferometer, in which two-dimensional output fringe intensity from a Mach-Zehnder interferometer with large radial shear is fed back, with the help of a video projector connected with a CCD camera, to an optically addressed phase-only liquid-crystal spatial light modulator. Experiments to verify the system performance have been conducted by use of an artificial eye consisting of a lens, an aberration plate, and a resolution test target. We observed that an image of the test target (mimicking a retina) blurred by the aberration plate (mimicking ocular aberrations) was successfully restored immediately after our adaptive optics system was activated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tomohiro Shirai. 2002-07-01. Liquid-crystal adaptive optics based on feedback interferometry for high-resolution retinal imaging.. https://doi.org/10.1364/ao.41.004013

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Digital imaging in the fabrication of ocular prostheses.

Several ocular and orbital disorders require surgical intervention that may result in ocular defects. The associated psychological effect of these defects on the patient requires immediate management and rehabilitation intervention by a team of specialists. The role of the maxillofacial prosthodontist in fabricating an ocular prosthesis with acceptable esthetics to restore facial symmetry and normal appearance for the anophthalmic patient becomes essential. This article presents a technique for fabricating ocular prostheses using the advantages of digital photography.

Eye, Artificial↗

The reliability of "Analyze" software in measuring orbital volume utilizing CT-derived data.

INTRODUCTION: Craniomaxillofacial surgeons require to estimate the orbital volume in a variety of clinical situations. This paper evaluates a new method based on software analysis of computerized tomography (CT) scan data. MATERIAL AND METHODS: Five dried skulls with prosthetic globes and periorbita were non-helically scanned in an Elscint 2400 CT scanner. Images obtained were processed using the "Analyze" software package and results compared to the volume of the intraorbital prosthesis as determined by a volume displacement gravimetric method. RESULTS: Estimates of volume produced by the software varied from the gold standard by 0.06-50.44%, with a mean error of 8.8%. CONCLUSION: Despite the use of a variety of scan protocols it was not possible to obtain results with "Analyze" software which were sufficiently accurate for clinical use.

Eye, Artificial↗