PubMed Health⌕ Search

PubMed · 12114176

Interactive computer simulations of knee-replacement surgery.

Abstract

OBJECTIVE: Current surgical training programs in the United States are based on an apprenticeship model. This model is outdated because it does not provide conceptual scaffolding, promote collaborative learning, or offer constructive reinforcement. Our objective was to create a more useful approach by preparing students and residents for operative cases using interactive computer simulations of surgery. Total-knee-replacement surgery (TKR) is an ideal procedure to model on the computer because there is a systematic protocol for the procedure. Also, this protocol is difficult to learn by the apprenticeship model because of the multiple instruments that must be used in a specific order. We designed an interactive computer tutorial to teach medical students and residents how to perform knee-replacement surgery. We also aimed to reinforce the specific protocol of the operative procedure. Our final goal was to provide immediate, constructive feedback. DESCRIPTION: We created a computer tutorial by generating three-dimensional wire-frame models of the surgical instruments. Next, we applied a surface to the wire-frame models using three-dimensional modeling. Finally, the three-dimensional models were animated to simulate the motions of an actual TKR. The tutorial is a step-by-step tutorial that teaches and tests the correct sequence of steps in a TKR. The student or resident must select the correct instruments in the correct order. The learner is encouraged to learn the stepwise surgical protocol through repetitive use of the computer simulation. Constructive feedback is acquired through a grading system, which rates the student's or resident's ability to perform the task in the correct order. The grading system also accounts for the time required to perform the simulated procedure. We evaluated the efficacy of this teaching technique by testing medical students who learned by the computer simulation and those who learned by reading the surgical protocol manual. Both groups then performed TKR on manufactured bone models using real instruments. Their technique was graded with the standard protocol. The students who learned on the computer simulation performed the task in a shorter time and with fewer errors than the control group. They were also more engaged in the learning process. DISCUSSION: Surgical training programs generally lack a consistent approach to preoperative education related to surgical procedures. This interactive computer tutorial has allowed us to make a quantum leap in medical student and resident teaching in our orthopedic department because the students actually participate in the entire process. Our technique provides a linear, sequential method of skill acquisition and direct feedback, which is ideally suited for learning stepwise surgical protocols. Since our initial evaluation has shown the efficacy of this program, we have implemented this teaching tool into our orthopedic curriculum. Our plans for future work with this simulator include modeling procedures involving other anatomic areas of interest, such as the hip and shoulder.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Stephen B Gunther, Gabriel E Soto, William W Colman. 2002. Interactive computer simulations of knee-replacement surgery.. https://doi.org/10.1097/00001888-200207000-00045

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The computer-assisted sequential lateral soft-tissue release in total knee arthroplasty for valgus knees.

Soft-tissue management is a critical factor in total knee arthroplasty, especially in valgus knees. The stepwise release has been based upon surgeon's experience. Computer-assisted surgery has gained increasing scientific interest in recent times and allows the intraoperative measurement of leg axis and gap size in extension and flexion. We therefore aimed to analyse the effect of sequential lateral soft-tissue release and the resulting change in the a.p. limb axis on the one hand and the tibiofemoral gaps on the other hand in extension as well as in flexion in eight cadaveric knees. Measurements were obtained using a CT-free navigation system. In extension the highest increase compared to the previous release step was found for the first (iliotibial band, P = 0.002), second (popliteus muscle, P = 0.0003), third (LCL, 0.007) and the sixth (entire PCL, P = 0.001) release step. In 90 degrees flexion all differences of the lateral release steps were statistically significant (P < 0.004). Massive progression of the lateral gap in flexion was found after the second (popliteus muscle, P = 0.004) and third (LCL, 0.007) release step. Computer-assisted surgery allows measurement of the effect of each release step of the sequential lateral release sequence and helps the surgeon to better assess the result.

Arthroplasty, Replacement, Knee↗

Isolated patellofemoral osteoarthritis.

Isolated patellofemoral osteoarthritis is now recognised to be more common than previously thought. The features and management are reviewed, including the various surgical options in symptomatic patients. The evidence base for managing patellofemoral osteoarthritis is behind that for the tibiofemoral joint. All treatments are based on uncontrolled observational case series, typically retrospectively reviewed. Fortunately the majority of patients with isolated patellofemoral degenerative changes do not need surgical treatment. Those who are symptomatic can usually be successfully treated with weight loss and quadriceps strengthening exercises.

Arthroplasty, Replacement, Knee↗

Stress analysis of the anterior tibial post in posterior stabilized knee prostheses.

Recent retrieval studies have indicated a high incidence of polyethylene wear on the anterior tibial post caused by impingement. This study investigated the influences of post-cam design features and component alignment on the stress distribution in the anterior tibial post when subjected to the impingement loading. Two three-dimensional finite element models of posterior stabilized knee prostheses were constructed, one with flat on flat (FF) and another with curve on curve (CC) contact surfaces between anterior tibial post and femoral cam. The polyethylene insert was modeled with elastoplastic properties. Nine cases, three hyperextension angles (0 degrees , 5 degrees , and 10 degrees ) combined with three axial tibial rotations (0 degrees , 2.5 degrees , and 5 degrees ) simulating different component alignments were analyzed. A vertical compressive load of 2,000 N and an extension moment of 45 Nm were applied simultaneously. The FF model had larger stress increases than the CC model in both hyperextension and tibial rotation compared with the neutral position. The maximum increase for the FF model was 68% in peak contact stress, 125% in von Mises stress, and 58% in tensile stress in the extreme case of 10 degrees of hyperextension combined with 5 degrees of axial rotation. Stress concentration was found at the anterior corner of the post in the FF model; this was not found in the CC model. The curve on curve design can reduce edge loading on the tibial post, especially during axial tibiofemoral rotation.

Arthroplasty, Replacement, Knee↗