PubMed Health⌕ Search

PubMed · 12162935

Specialized lipid profiles.

Abstract

Individuals with abnormal blood lipids and lipoproteins are at increased risk for cardiovascular disease. With the development of effective dietary, behavioral, and pharmaceutical treatments to optimize blood lipoproteins, accurate clinical assessment of blood lipids and lipoproteins are essential for patient management and research. This article discusses the use of a variety of lipid analyses currently available. The use of traditional lipoprotein measurements, including Friedewald calculation of low-density lipoprotein (LDL) cholesterol and ultracentrifugation methods to measure blood lipoproteins, are discussed. Newer analytic techniques, including the vertical analytic profile, nuclear magnetic resonance, direct LDL measurement, LDL size determination, and triglyceride-rich lipoprotein remnants, are also described. Despite the development of a number of lipid and lipoprotein assays, lipoprotein analysis with a Friedewald- calculated LDL measurement remains the lipoprotein analysis performed in approximately 93% of clinical laboratories. It remains to be determined if the alternative lipid and lipoprotein assays currently available will become more widely utilized in the future.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Karen E Friday. 2002. Specialized lipid profiles.. https://doi.org/10.1007/s11883-002-0073-8

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Detection of Delta9-tetrahydrocannabinolic acid A in human urine and blood serum by LC-MS/MS.

Delta9-tetrahydrocannabinolic acid A (Delta9-THCA-A) is the precursor of Delta9-tetrahydrocannabinol (Delta9-THC) in hemp plants. During smoking, the non-psychoactive Delta9-THCA-A is converted to Delta9-THC, the main psychoactive component of marihuana and hashish. Although the decarboxylation of Delta9-THCA-A to Delta9-THC was assumed to be complete--which means that no Delta9-THCA-A should be detectable in urine and blood serum of cannabis consumers--we found Delta9-THCA-A in the urine and blood serum samples collected from police controls of drivers suspected for driving under the influence of drugs (DUID). For LC-MS/MS analysis, urine and blood serum samples were prepared by solid-phase extraction. Analysis was performed with a phenylhexyl column using gradient elution with acetonitrile. For detection of Delta9-THCA-A, the mass spectrometer (MS) (SCIEX API 365 triple-quadrupole MS with TurboIonSpray source) was operated in the multiple reaction monitoring (MRM) mode using the following transitions: m/z357 --> 313, m/z357 --> 245 and m/z357 --> 191. Delta9-THCA-A could be detected in the urine and blood serum samples of several cannabis consumers in concentrations of up to 10.8 ng/ml in urine and 14.8 ng/ml in serum. The concentration of Delta9-THCA-A was below the Delta9-THC concentration in most serum samples, resulting in molar ratios of Delta9-THCA-A/Delta9-THC of approximately 5.0-18.6%. Only in one case, where a short elapsed time between the last intake and blood sampling is assumed, the molar ratio was 18.6% in the serum. This indicates differences in elimination kinetics, which need to be investigated in detail.

Blood Chemical Analysis↗