Spinal cord stimulation electrode design: prospective, randomized, controlled trial comparing percutaneous and laminectomy electrodes-part I: technical outcomes.

Abstract

OBJECTIVE: The clinical use of spinal cord stimulation for treatment of chronic intractable pain has been increasingly successful because of recent technical improvements, particularly the development of multiple-contact electrodes supported by programmable implanted pulse generators. Contemporary electrodes can be placed percutaneously in some cases and require a limited laminectomy in other cases. METHODS: We performed a prospective, randomized, controlled trial comparing two prototypical electrode designs, using a computerized system that allows direct patient interaction and quantitative measurements. A series of 24 patients with chronic lumbosacral pain syndromes first underwent testing with percutaneous four-contact electrodes and then underwent implantation, at the same spinal level, of one of two different electrode configurations; 12 patients received a new percutaneous four-contact electrode of the same design and 12 received an insulated four-contact array, which was implanted via laminectomy. RESULTS: The insulated array performed significantly (P = 0.0005-0.0047) better than the temporary percutaneous electrode for the same patients, according to all three measures tested (ratings of paresthesia coverage of pain, coverage calculated from patient drawings, and amplitudes), at the "usage" amplitude for the three standard bipoles examined. The insulated array also performed significantly (P = 0.0000-0.026) better than the permanent percutaneous electrode in terms of coverage ratings and amplitude requirements. Low back coverage ratings were significantly better for the insulated array than for the temporary percutaneous electrode, and scaled amplitudes necessary for low back coverage were significantly better for the permanent percutaneous electrode than for the temporary electrode. In comparison with the percutaneous temporary electrode, at subjectively identical stimulation intensities, the permanent insulated array required significantly lower amplitude. CONCLUSION: We can immediately infer from these technical data that the use of an insulated array, in comparison with a percutaneous electrode, would double battery life. Extended follow-up monitoring will be required to assess the extent to which the technical advantages we observed for the insulated array might be associated with improved clinical outcomes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Richard B North, David H Kidd, John C Olin, Jeffrey M Sieracki. 2002. Spinal cord stimulation electrode design: prospective, randomized, controlled trial comparing percutaneous and laminectomy electrodes-part I: technical outcomes.. https://pubmed.ncbi.nlm.nih.gov/12182776/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Modeling biological motor control for human locomotion with functional electrical stimulation.

This paper develops a novel control system for functional electrical stimulation (FES) locomotion, which aims to generate normal locomotion for paraplegics via FES. It explores the possibility of applying ideas from biology to engineering. The neural control mechanism of the biological motor system, the central pattern generator, has been adopted in the control system design. Some artificial control techniques such as neural network control, fuzzy logic, control and impedance control are incorporated to refine the control performance. Several types of sensory feedback are integrated to endow this control system with an adaptive ability. A musculoskeletal model with 7 segments and 18 muscles is constructed for the simulation study. Satisfactory simulation results are achieved under this FES control system, which indicates a promising technique for the potential application of FES locomotion in future.

Electric Stimulation Therapy↗

Complications and troubleshooting of two-stage sacral neuromodulation therapy: a single-institution experience.

OBJECTIVES: With the increasing use of sacral neuromodulation therapy, urologists are faced with postimplantation challenges. The purpose of this study was to identify these events and their causes and management in our large single-institution experience. METHODS: From July 2002 to September 2004, all patients who underwent sacral neuromodulation therapy for refractory bladder conditions were identified. Their medical records were retrospectively evaluated for history, operative intervention, and programming visits. Events after implantation of the implantable pulse generator (IPG) unit were noted. The evaluation, troubleshooting, management, and resolution of events at the last follow-up visit were extracted. RESULTS: A total of 214 patients underwent sacral neuromodulation therapy at our institution. The mean patient age was 53.5 +/- 15.4 years. Of the 214 patients, 161 underwent IPG implantation during a mean follow-up period of 16 months (range 5 to 30). The second-stage explantation and revision rate was 10.5% and 16.1%, respectively. The indications for explantation were infection (8 of 17) and failure to maintain a response (9 of 17). Revisions were done for decreases in response with abnormal (12 of 26) or normal (5 of 26) impedance measurements, IPG site discomfort (4 of 26), draining sinus at the IPG site (4 of 26), and lead migration (1 of 26). Equalization of impedance measurements was the most commonly observed impedance abnormality. These were managed by drying fluid from the connection in 4 patients and lead change in the rest. CONCLUSIONS: After IPG implantation, a decline in response may occur. Although some were explanted, most were revised, with most of the revisions functional on follow-up. Familiarity with impedance evaluation and development of algorithms for postimplant management are essential for troubleshooting and maintenance of the device.

Electric Stimulation Therapy↗