PubMed Health⌕ Search

PubMed · 12197402

[Changes in hemostasis in malignant diseases].

Abstract

Tumourous diseases are associated with haemorrhagic as well as thrombotic complications. The most frequent cause of haemorrhagic states in tumourous diseases is thrombocytopenic haemorrhage, consumption coagulopathy and activated fibrinolysis. Trousseau described in 1865 a mutual association between tumourous diseases and venous thromboembolism. As many as 15-20% patients with venous thromboembolism have an undetected malignity which is a prevalence of 2-3% in the population. From this ensues the relative risk of a newly diagnosed malignity which is higher during the first year after venous thromboembolism. The prevalence varies between 2% and 6%. Migrating thrombophlebitiis (saltans and migrans) are a relatively specific sign in tumours, in particular in pancreatic tumours. In the pathogenesis of venous thromboembolisms in tumourous diseases in particular the following factors play a part: elevated coagulation parameters, reduced fibrinolysis, frequent immobilization, surgical operations in the case-history, chemotherapy, hormonal therapy and central venous catheters. The authors present a brief review of changes of haemostasis in tumourous diseases, their possible diagnosis and possible pharmacological prevention and treatment of thromboembolisms.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Malý, M Blazek, M Bláha, M Pecka. 2002. [Changes in hemostasis in malignant diseases].. https://pubmed.ncbi.nlm.nih.gov/12197402/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Molecular characterization of an Italian patient with plasminogen deficiency and ligneous conjunctivitis.

Plasminogen deficiency is a rare disease characterized by ligneous conjunctivitis and infections. We observed a 3-year-old Italian boy presenting ligneous conjunctivitis and low plasma levels of plasminogen. Twenty-three different mutations on the PLG gene have been reported to date, but mutation analysis had been troublesome for the presence of highly homologous genes. The aim of the study was to identify the underlying mutation avoiding coamplification of unwanted genetic materials using a long polymerase chain reaction strategy, instead of the previously reported subcloning methods. By this simple strategy the complete sequence analysis of PLG gene was performed, and a previously reported missense homozygous mutation (K19E) was identified.

Blood Coagulation Disorders↗

Diagnosis of early coagulation abnormalities in trauma patients by rotation thrombelastography.

BACKGROUND: Reagent-supported thromboelastometry with the rotation thrombelastography (e.g. ROTEM) is a whole blood assay that evaluates the visco-elastic properties during blood clot formation and clot lysis. A hemostatic monitor capable of rapid and accurate detection of clinical coagulopathy within the resuscitation room could improve management of bleeding after trauma. OBJECTIVES: The goals of this study were to establish whether ROTEM correlated with standard coagulation parameters to rapidly detect bleeding disorders and whether it can help to guide transfusion. METHODS: Ninety trauma patients were included in the study. At admission, standard coagulation assays were performed and ROTEM parameters such as clot formation time (CFT) and clot amplitude (CA) were obtained at 15 min (CA(15)) with two activated tests (INTEM, EXTEM) and at 10 min (CA(10)) with a test analyzing specifically the fibrin component of coagulation (FIBTEM). RESULTS: Trauma induced significant modifications of coagulation as assessed by standard assays and ROTEM. A significant correlation was found between prothrombin time (PT) and CA(15)-EXTEM (r = 0.66, P < 0.0001), between activated partial thromboplastin time and CFT-INTEM (r = 0.91, P < 0.0001), between fibrinogen level and CA(10)-FIBTEM (r = 0.85, P < 0.0001), and between platelet count and CA(15)-INTEM (r = 0.57, P < 0.0001). A cutoff value of CA(15)-EXTEM at 32 mm and CA(10)-FIBTEM at 5 mm presented a good sensitivity (87% and 91%) and specificity (100% and 85%) to detect a PT > 1.5 of control value and a fibrinogen less than 1 g L(-1), respectively. CONCLUSIONS: ROTEM is a point-of-care device that rapidly detects systemic changes of in vivo coagulation in trauma patients, and it might be a helpful device in guiding transfusion.

Blood Coagulation Disorders↗