Output variation from an intensity modulating dynamic collimator.

Abstract

Intensity modulated radiation therapy (IMRT) offers a method of delivering radiation dose conforming to the shape of targets while minimizing the dose to the surrounding tissue and nearby critical organs. One popular device is the NOMOS MIMiC Collimator coupled to the CORVUS treatment planning system. The MIMiC collimator, mounted on a linac head, opens and closes one or more of its 40 small leaves as determined by the planner while the linac delivers radiation and the gantry rotates. This dynamic IMRT allows the intensity to be modulated yielding a highly conformal dose distribution. However, the dose output becomes a function of the detailed manner in which the leaves open and close, since the opening and closing are not instantaneous. We investigate the effect of switch rates and delay in the open/close events on the output profiles. The output is enhanced as the switch rate increases. The enhancement factor at any point of measurement is dependent on its distance from the central plane. We interpret these variations in terms of a simple model, which includes the effect of leaf travel time during the process of opening and closing. We also include the time delay in establishing the specified pressure in the pneumonic device, which controls the opening and closing of the leaves. The information presented here offers a means for incorporating these output changes into the planning system. This may avoid the current situation where many patient plans need to be renormalized based on the actual measurement taken during the delivery of the specified intensity pattern to a phantom.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Murshed Hossain, Christopher J Houser, James M Galvin. 2002. Output variation from an intensity modulating dynamic collimator.. https://doi.org/10.1118/1.1493782

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Measurement of polyethylene wear in total hip arthroplasty--accuracy versus ease of use.

The aim of this study was to compare the accuracy of four different methods for measuring wear using an apparatus that simulates known amounts of three dimensional wear. Wear was measured using the manual methods reported by Charnley, Livermore, Dorr and Wan and the computerized method reported by Devane. Only the method reported by Devane measured the three-dimensional (superior and anterior) wear with a reasonable accuracy, with a mean measurement error of 0.21 mm. With superior wear alone, Charnley's method underestimated the extent of wear by 16.6%, with a mean error of 0.35 mm; Livermore's method estimated wear to within 9.5%, with a mean error of 0.16 mm; Devane's method estimated wear to within 9.5%, with a mean error of 0.15 mm; and Dorr's method underestimated wear by 25.4%, with a mean error of 0.56 mm. Dorr's method was modified as a result of the experimental tests. The clinical application of the new method showed comparable data to that using the Devane method. In conclusion, this new method can be used to estimate the average wear in groups of patients accurately.

Equipment Failure Analysis↗

Survey of parallel slat collimator designs for hybrid PET imaging.

Hybrid PET gamma cameras with coincidence detection electronics are commonly equipped with parallel slat collimators in order to reduce detection of singles and scattered photons, and create a pseudo-2D imaging geometry. The objective of this work was to survey a broad range of parallel slat collimator designs using a series of Monte Carlo simulated PET acquisitions. Collimator properties including septal height, septal thickness and pitch were independently examined over a wide range of values. Simulations were performed for hybrid PET imaging of a long cylindrical phantom uniformly filled with water and radioactivity. The performance for each collimator design was evaluated in terms of the trues-to-singles ratio, scatter fraction, and noise equivalent count rate for a wide range of camera trigger rates. Results indicate that increasing septal height offers the biggest performance gain. Septal thickness should be at least 0.5 mm, and should be optimized in conjunction with pitch to obtain the best performance. This survey provides the groundwork necessary for optimizing slat collimators, and provides a starting point for investigating new slat collimator designs.

Equipment Failure Analysis↗