Fast 31P chemical shift imaging using SSFP methods.

Abstract

Steady-state free precession (SSFP) methods have been very successful due to their high signal and short imaging times. These properties make them good candidates for applications that intrinsically suffer from low signal such as low gamma nuclei imaging. A new chemical shift imaging (CSI) technique based on the SSFP signal formation has been implemented and applied to (31)P. The signal properties of the SSFP CSI method have been evaluated and the steady-state signal of (31)P has been measured in human muscles. Due to the T(2) and T(1) signal dependence of SSFP, the steady-state signal mainly consists of phosphocreatine (PCr). The technique allows fast CSI acquisitions with high SNR of the PCr signal. The SNR gain for PCr over a FLASH-based CSI method is approx. 4-5. Fast in vivo CSI of human muscle with subcentimeter resolution and high SNR is demonstrated at 2 T.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

O Speck, K Scheffler, J Hennig. 2002. Fast 31P chemical shift imaging using SSFP methods.. https://doi.org/10.1002/mrm.10279

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultra-high-field 7T MRI reveals neural abnormalities of attention networks in relation to cognitive impairment in hypertension.

Hypertension is a significant risk factor for cognitive impairment (CI), yet the corresponding neural network abnormalities remain underexplored. In this study, we examined the associations among global and domain-specific cognitive dysfunction, neuroimaging measures, and blood pressure in a subgroup of hypertensive patients with CI (N = 41) from a randomized controlled trial who underwent ultra-high-field 7 T MRI. Structural atrophy related to CI was localized to regions overlapping the attention networks. Both whole-brain and within-network dysfunction of the attention networks were associated with worse global cognitive performance. Notably, hyperconnectivity within key attention network hubs, including the right anterior insula and posterior intraparietal sulcus, was associated with declined processing speed in hypertensive patients, mediating the association between pulse pressure and processing speed. These findings provide new insights into the neural pathophysiology of hypertension-related CI and suggest potential network-based targets for intervention.

Magnetic Resonance Imaging↗

Is TrueFISP a gradient-echo or a spin-echo sequence?

It is commonly accepted that TrueFISP (balanced FFE, FIESTA) belongs to the class of gradient-echo (GRE) sequences. GRE sequences are sensitive to dephasing effects of the transverse magnetization between the excitation pulse and echo acquisition, and phase coherence is only established directly after and before excitation pulses. However, an analysis of the phase evolution of transverse magnetization in a TrueFISP experiment shows very close similarities to the echo formation of a spin-echo (SE) experiment. If dephasing between excitation pulses is below +/-pi, TrueFISP exhibits a nearly complete refocusing of transverse magnetization at TE = TR/2. Only signals acquired before and after TR/2 show an additional T*2 sensitivity.

Magnetic Resonance Imaging↗

Detecting stiff masses using strain-encoded (SENC) imaging.

A method is proposed for detecting stiff masses using strain-encoded (SENC) magnetic resonance imaging (MRI). An object of interest is compressed to produce local strain distribution that depends on local elasticity, where intensities correlate with the local through-imaging-plane strain component. Because the strain is lower inside a stiff mass than in the surrounding soft tissue, an intensity contrast in the resulting images would enable direct detection of the mass without postprocessing. The technique was validated by a phantom experiment in which a gel phantom with a stiff region was used. The advantages of the proposed method include short imaging time and uncomplicated postprocessing. However, in its current form the technique does not measure elasticity.