PubMed Health⌕ Search

PubMed · 12353287

High-order multiband encoding in the heart.

Abstract

Spatial encoding with multiband selective excitation (e.g., Hadamard encoding) has been restricted to a small number of slices because the RF pulse becomes unacceptably long when more than about eight slices are encoded. In this work, techniques to shorten multiband RF pulses, and thus allow larger numbers of slices, are investigated. A method for applying the techniques while retaining the capability of adaptive slice thickness is outlined. A tradeoff between slice thickness and pulse duration is shown. Simulations and experiments with the shortened pulses confirmed that motion-induced excitation profile blurring and phase accrual were reduced. The connection between gradient hardware limitations, slice thickness, and flow sensitivity is shown. Excitation profiles for encoding 32 contiguous slices of 1-mm thickness were measured experimentally, and the artifact resulting from errors in timing of RF pulse relative to gradient was investigated. A multiband technique for imaging 32 contiguous 2-mm slices, with adaptive slice thickness, was developed and demonstrated for coronary artery imaging in healthy subjects. With the ability to image high numbers of contiguous slices, using relatively short (1-2 ms) RF pulses, multiband encoding has been advanced further toward practical application.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Charles H Cunningham, Graham A Wright, Michael L Wood. 2002. High-order multiband encoding in the heart.. https://doi.org/10.1002/mrm.10277

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Uterine artery Doppler blood flow in cases of hydatidiform mole and its correlation with beta-hCG.

OBJECTIVES: To study the correlation between Doppler blood flow and beta-human chorionic gonadotropin (hCG), to assess the course of the disease and the follow up evaluation. SETTING: This study was conducted in Assiut University Hospital, Department of Obstetrics and Gynecology. DESIGN: Longitudinal study. SUBJECTS AND METHODS: Fifteen cases of vesicular mole were recruited and followed up. The patients were evaluated the day before evacuation of the uterus. This included clinical assessment, Doppler uterine artery blood flow velocity waveforms using the Doppler indices and assessment of the serum level of beta-hCG. These cases were followed up every 2 weeks in the first 2 months, and every month thereafter until the 6 month. RESULTS: Twelve patients showed continuous decrease in beta-hCG level from 1192+/-697 to 6+/-11 IU/ml by the end of the second month. Systolic-diastolic (S/D) increased from (2.57+/-1.13) to (15.9+/-2.07) (P<0.0001), RI increased from 0.55+/-0.15 to 1.0+/-0.26(P<0.0001) and PI increased from 1.02+/-0.47 to 6.12+/-2.34 (P<0.0001). One patient showed a fluctuating level of beta-hCG around the same level, and two showed a slowed decrease. Doppler indices showed similar results. There is a strong correlation between beta-hCG and all Doppler indices throughout the course of follow up: beta-hCG and S/D r<0.01, beta-hCG and RI r<0.01 and beta-hCG and PI r<0.01. CONCLUSION: Doppler ultrasound can be used as an adjuvant tool in the follow up of cases of vesicular mole and can predict the progress in the course of the disease.

Arteries↗

Effect of non-linearity in predicting Doppler waveforms through a novel model.

BACKGROUND: In pregnancy, the uteroplacental vascular system develops de novo locally in utero and a systemic haemodynamic & bio-rheological alteration accompany it. Any abnormality in the non-linear vascular system is believed to trigger the onset of serious morbid conditions like pre-eclampsia and/or intrauterine growth restriction (IUGR). Exact Aetiopathogenesis is unknown. Advancement in the field of non-invasive doppler image analysis and simulation incorporating non-linearities may unfold the complexities associated with the inaccessible uteroplacental vessels. Earlier modeling approaches approximate it as a linear system. METHOD: We proposed a novel electrical model for the uteroplacental system that uses MOSFETs as non-linear elements in place of traditional linear transmission line (TL) model. The model to simulate doppler FVW's was designed by including the inputs from our non-linear mathematical model. While using the MOSFETs as voltage-controlled switches, a fair degree of controlled-non-linearity has been introduced in the model. Comparative analysis was done between the simulated data and the actual doppler FVW's waveforms. RESULTS & DISCUSSION: Normal pregnancy has been successfully modeled and the doppler output waveforms are simulated for different gestation time using the model. It is observed that the dicrotic notch disappears and the S/D ratio decreases as the pregnancy matures. Both these results are established clinical facts. Effects of blood density, viscosity and the arterial wall elasticity on the blood flow velocity profile were also studied. Spectral analysis on the output of the model (blood flow velocity) indicated that the Total Harmonic Distortion (THD) falls during the mid-gestation. CONCLUSION: Total harmonic distortion (THD) is found to be informative in determining the Feto-maternal health. Effects of the blood density, the viscosity and the elasticity changes on the blood FVW are simulated. Future works are expected to concentrate mainly on improving the load with respect to varying non-linear parameters in the model. Heart rate variability, which accounts for the vascular tone, should also be included. We also expect the model to initiate extensive clinical or experimental studies in the near future.

Arteries↗

Arterial anatomy of the auricle: its importance for reconstructive surgery.

Because the auricle is an organ that is both used as a flap in reconstructive surgery and is often exposed to trauma, the arterial distribution of the auricle is of great importance. The aims of this study were to investigate the auricular branches of the posterior auricular artery (PAA) and superficial temporal artery (STA), to determine the vascular territory of various auricular flaps for flap design. Fifteen human male cadaver auricles were used for this study. A branch of the STA to the ear lobe (lower branch) was present in only five auricles (33%). Branches distributing the tragus were small and short arterioles (middle branch of the STA) which were present in 14 auricles (93%). The upper branch of the STA ascends the ascending helix, giving off sub-branches. Some of these sub-branches traverse to the posterior surfaces of the ear and communicate with branches of the PAA. The upper branch was present in all auricles. In 10 auricles (67%), the PAA terminated on the posterior auricular surface, whereas in five auricles (33%) it continued and distributed to the parietotemporal area. The arterial network which was obvious in the middle region of the posterior auricular surface was formed from the middle branch and some sub-branches of the upper branch of the PAA, which was found in 10 auricles (67%). We are convinced that the PAA is the dominant artery for the auricle and the arterial network of posterior auricular surface is better developed in the middle region than the other regions.

Arteries↗