Accelerated stability model for predicting shelf-life.

Abstract

Second- and higher-order degradation reactions sometimes cannot be approximated with linear or exponential relationships and need to be appropriately modeled. Events above the COULTER HmX Analyzer white blood cell (WBC) counting threshold were recorded for the HmX PAK reagent system stored at five elevated temperatures. An accelerated stability model for a second-degree polynomial degradation pattern was used. The shelf-life of the reagent, along with 95% lower bound confidence intervals, is predicted using the same pattern of degradation as well as the Arrhenius approximation. Experiments indicated that the degradation of the HmX PAK reagent occurred in two phases, the lag phase and the degradation phase, in all tested temperatures. The phase durations are temperature-dependent, and the Arrhenius approximation is appropriate (P=0.639). The degradation of the reagent during the lag phase was experimentally undetectable. Changes of the reagent were nonsignificant for a predicted period of 164 days at 25 degrees C. The rate of degradation increased significantly later on during the degradation phase. The lower bound of the 95% confidence interval of this prediction indicated that it would take at least 326 days before the HmX PAK reagent would have any performance issue related to aging at storage temperature.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Robert T Magari, Kevin P Murphy, Tracey Fernandez. 2002. Accelerated stability model for predicting shelf-life.. https://doi.org/10.1002/jcla.10043

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Liquid chromatographic determination of natural and synthetic colorants in lyophilized foods using an automatic solid-phase extraction system.

Five synthetic and five natural colorants were determined in lyophilized dairy products and fatty foods using an automatic method based on lixiviation and a solid-phase extraction process that includes cotton and RP-C(18) columns for the sequential retention of synthetic colorants and natural colorants, respectively. The lyophilization of the sample coupled with the separation procedure provides clean extracts despite the complexity of the matrices studied. In addition, the lyophilization process preserves the sample for at least 2 months without changes in the concentrations of the colorants. Identification and determination of synthetic and natural colorants were carried out using a liquid chromatograph equipped with a diode array detector. The detection limits achieved for all of the colorants (0.03-75 microg/g of lyophilized sample) allowed their determination within the limits established by the European Union, with good precision (approximately 4.5%). In addition, colorants spiked to different foods provided average recoveries (spiked at three concentration levels in four types of dairy samples and in three types of fatty foods) near 94 +/- 4%.

Autoanalysis↗

Automated determination of selected water-soluble vitamins in tablets using a bench-top robotic system coupled to reversed-phase (RP-18) HPLC with UV detection.

The determination of folic acid, nicotinamide, nicotinic acid, riboflavin, riboflavin-5'-phosphate, pyridoxine and thiamine in tablets has been successfully automated using a bench-top robotic system (Zymark Tablet Processing Workstation II) coupled to reversed-phase (RP-18) HPLC with UV-detection. The new automated methods have been validated and were found to be applicable in routine analysis for all common types of multivitamin tablets. The precision is exemplified by relative standard deviations of 5.4% for folic acid, 2.1% for nicotinamide, 1.6% for pyridoxine, 0.7% for riboflavin and 1.1% for thiamine using film-coated tablets as sample. Mean recoveries obtained during spiking experiments were in the range of 95.2-103.9%.

Autoanalysis↗