PubMed Health⌕ Search

PubMed · 12378077

Temporal lobe epilepsy -current wisdom.

Abstract

Issues related to resective surgery for patients with medically refractory temporal lobe epilepsy (TLE) who have mesial temporal sclerosis (MTS), those with normal imaging, and the related issue of those at risk for verbal memory deficits are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G A Ojemann. 2001. Temporal lobe epilepsy -current wisdom.. https://doi.org/10.1159/000064607

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Imaging of vascular gene therapy.

Gene therapy is an exciting frontier in medicine today. Many genes have been shown to be useful for treatment of various vascular diseases, including chronic cardiac and limb ischemia syndromes, vasculoproliferative disorder, hypercholesterolemia, atherosclerosis, thrombosis, and hypertension. Precise delivery of genes into target vessels, efficient transfer of genes into vascular cells of the target, and prompt assessment of gene expression over time are three challenging tasks for successful vascular gene therapy. Thus, in vivo imaging methods that can be used to monitor gene delivery and localize gene expression are needed. Modern imaging techniques provide an opportunity to monitor and direct vascular gene therapy. Radiologists play a key role not only in developing and mastering endovascular genetic interventions but also in assessing the success of vascular gene therapy and directing further refinement of vascular gene therapy technology. This article provides an overview of the current status of imaging of vascular gene therapy.

Diagnostic Imaging↗

The use of optical fiber bundles combined with electrochemistry for chemical imaging.

The present Review describes the progress made in using imaging optical fiber bundles for fluorescence and electrochemical-initiated chemiluminescence imaging. A novel optoelectrochemical micro-ring array has been fabricated and demonstrated for concurrent electrochemical and optical measurements. The device comprises optical fibers coated with gold via electroless gold deposition and assembled in a random array format. The design yielded an array of approximately 200 micro-ring electrodes, where interdiffusional problems were minimized. The inner diameter of the ring electrode is fixed by the diameter of the individual optical fibers (25 microns), while the outer radius is determined by the thickness of the deposited gold. While all the fibers are optically addressable, they are not all electrochemically addressable. The resolution of this device is in the tens of micrometers range, determined by the diameter of the optical fiber (25 microns) and by the spacing between each electrically connected fiber. For the purpose of having well-behaved microelectrode characteristics, this spacing was designed to be larger than 60 microns. The array was characterized using ferrocyanide in aqueous solution as a model electroactive species to demonstrate that this microelectrode array format exhibits steady-state currents at short response times. This device has potential application to be used as an optoelectronic sensor, especially for the electrolytic generation and transmission of electrochemiluminescence, and was used to demonstrate that electrochemically generated luminescent products can be detected with the fiber assembly.

Diagnostic Imaging↗

[Renal trauma: is open surgery still up to date?].

For several years conservative treatment of renal trauma has been increasing. Investigation of circulatory conditions, renal ultrasound, and CT scan are necessary for assessing the extent of renal injury by the exact classifications of the organ injury scale. Through close cooperation of all departments involved, especially intensive care, traumatology, general surgery, radiology, and urology, it should be possible to limit primarily operative open surgery to life-threatening renal bleeding (grade V). All other cases require a repeat diagnosis for control purposes after 2-4 days. Complications found then can for the most part be treated conservatively or by minimally invasive techniques. Thus, open operative intervention has been minimized in these cases too.

Diagnostic Imaging↗