Proficiency testing performance: a case study with modeling.

Abstract

OBJECTIVES: Previous literature has approached proficiency testing (PT) performance by defining the minimum levels, and combinations of imprecision and bias, necessary to meet PT requirements. In this case report, current PT performance was assessed and modeling performed to prioritize our quality improvement efforts. METHODS: A total of 1,006 chemistry challenge results from Ontario's Laboratory Proficiency Testing Program (LPTP, now QMPLS) performed on 69 tests during 1999 and 2000 were used for this retrospective analysis. Peer group means, all method means and results from reference labs were used for comparison. QMPLS flagging and recommended performance criteria were compiled, and modeling performed to predict different levels of performance. RESULTS: Our internal imprecision is <5% for 72% of our 69 tests; however, only 20% of our tests had a CV/PT <25%. Of the 1,006 challenges performed, 136 (13.5%) results were outside PT limits, 55 (5.5%) results were flagged, and 12 requests were received from QMPLS seeking clarification on 24 (2.4%) results. Follow-up identified 9 (38%) nonanalytical errors, 8 (33%) method bias errors, 4 (17%) random errors, 2 poor methods, and one with no error identified. Modeling predicted flagging rates of 2.4% using QMPLS recommended precision performance, 1.6% using our current internal imprecision, 2.2% or 7.0% if we included an overall 20% or 50% relative bias rate with our current imprecision levels, or 15.0% when an estimate of our actual bias for each analyte was considered along with our current imprecision levels. CONCLUSIONS: If imprecision were the only cause of PT errors, our flagging rate for this study period would be 1.6%, and we would need to formally investigate 8 results a year. In practice, strict application of the QMPLS PT criteria would result in 68 investigations annually; however, judicial review of the results before request for clarification significantly reduced this number to 12 investigations (of which 38% were nonanalytical errors). At the present time bias is a significant cause of poor PT performance in a variety of assays. Individual laboratories need to address the problem of bias, and ultimately so do manufacturers. It would be helpful if PT programs also acknowledged this necessary evolution in both their criteria and processes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jennifer M Waugh, Christine P Collier, Andrew G Day, Mary Waugh, Michael J Raymond. 2002. Proficiency testing performance: a case study with modeling.. https://doi.org/10.1016/s0009-9120(02)00337-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Capillary electrophoresis and its application in the clinical laboratory.

Over the past 10 years, capillary electrophoresis (CE) is an analytical tool that has shown great promise in replacing many conventional clinical laboratory methods, especially electrophoresis and high performance liquid chromatography (HPLC). The main attraction of CE was that it was fast, used small amounts of sample and reagents, and was extremely versatile, being able to separate large and small analytes, both neutral and charged. Because of this versatility, numerous methods for clinically relevant analytes have been developed. However, with the exception of the molecular diagnostic and forensic laboratories CE has not had a major impact. A possible reason is that CE is still perceived as requiring above-average technical expertise, precluding its use in a laboratory workforce that is less technically adept. With the introduction of multicapillary instruments that are more automated, less technique-dependent, in addition to the availability of commercial and cost effective test kit methods, CE may yet be accepted as a instrument routinely used in the clinical laboratories. Thus, this review will focus on the areas where CE shows the most potential to have the greatest impact on the clinical laboratory. These include analysis of proteins found in serum, urine, CSF and body fluids, immunosubstraction electrophoresis, hemoglobin variants, lipoproteins, carbohydrate-deficient transferrin (CDT), forensic and therapeutic drug screening, and molecular diagnostics.

Chemistry, Clinical↗

Tandem mass spectrometry in the clinical chemistry laboratory.

Tandem mass spectrometry is becoming an increasingly important analytical technology in the clinical laboratory environment. Applications in toxicology and therapeutic drug monitoring have opened the door for tandem mass spectrometry and now we are seeing a vast array of new applications being developed. It has been the combination of tandem mass spectrometry with sample introduction techniques employing atmospheric pressure ionization that has enabled this technology to be readily implemented in the clinical laboratory. Although its major research applications started with pharmacology and proteomics, tandem mass spectrometry is being used for a great variety of analyses from steroids to catecholamines to peptides. As with chromatographic methods, tandem mass spectrometry is most cost effective when groups of compounds need to be measured simultaneously. However as the price/performance of this technology continues to improve, it will become even more widely utilized for clinical laboratory applications.

Chemistry, Clinical↗

Development of a sensitive high-performance liquid chromatography method for the detection of 667 COUMATE in vivo.

Steroid sulphatase inhibitors which decrease or prevent the biosynthesis of oestrogens, potentially have an important role in the treatment of breast cancer in postmenopausal women. The non-steroidal sulphatase inhibitor 667 COUMATE has been shown to be active both in vitro and in vivo. The pharmacokinetics of this drug have not been investigated. In preparation for the clinical evaluation of this agent, a sensitive and robust reversed phase high-performance liquid chromatography (HPLC) method was developed for the detection of 667 COUMATE in biological fluids. The sulphatase inhibitor was extracted from plasma with diethyl ether and separated from putative metabolites and endogenous plasma components with a C3-phenyl column. Using this method an extraction efficiency of 76+/-5% and a limit of detection of less than 0.1 ng/ml was achieved. The stability of this agent was investigated under different pH conditions and during storage in plasma at room temperature or -20 degrees C. 667 COUMATE was found to be stable when stored in acidified plasma (pH 4.5) at -20 degrees C. In conclusion, the HPLC method developed is a reproducible and sensitive assay that will enable quantitation of the potent non-steroidal sulphatase inhibitor 667 COUMATE in biological fluids in the forthcoming Phase I clinical trial.

Chemistry, Clinical↗