PubMed Health⌕ Search

PubMed · 12416326

New biointeracting materials.

Abstract

This article reports on advances in haemocompatible and antimicrobial coatings. A polymer is described that has nonthrombogenic and antithrombogenic properties on the same polymer backbone, which prevents protein adsorption and inhibits thrombin at the same time. A separate polymer formulation has also been developed that is reportedly biocompatible, lubricious and antimicrobial.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Shivpal Sandhu, Ajay Luthra. 2002. New biointeracting materials.. https://pubmed.ncbi.nlm.nih.gov/12416326/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Stable and controlled amphoteric doping by encapsulation of organic molecules inside carbon nanotubes.

Single-walled carbon nanotubes (SWNTs) have strong potential for molecular electronics, owing to their unique structural and electronic properties. However, various outstanding issues still need to be resolved before SWNT-based devices can be made. In particular, large-scale, air-stable and controlled doping is highly desirable. Here we present a method for integrating organic molecules into SWNTs that promises to push the performance limit of these materials for molecular electronics. Reaction of SWNTs with molecules having large electron affinity and small ionization energy achieved p- and n-type doping, respectively. Optical characterization revealed that charge transfer between SWNTs and molecules starts at certain critical energies. X-ray diffraction experiments revealed that molecules are predominantly encapsulated inside SWNTs, resulting in an improved stability in air. The simplicity of the synthetic process offers a viable route for the large-scale production of SWNTs with controlled doping states.

Coated Materials, Biocompatible↗

Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions.

BACKGROUND: Early clinical studies demonstrated the feasibility of local paclitaxel delivery in reducing restenosis after treatment of de novo coronary lesions in small patient populations. METHODS AND RESULTS: We conducted a randomized, double-blind trial of 536 patients at 38 medical centers evaluating slow-release (SR) and moderate-release (MR) formulations of a polymer-based paclitaxel-eluting stent (TAXUS) for revascularization of single, primary lesions in native coronary arteries. Cohort I compared TAXUS-SR with control stents, and Cohort II compared TAXUS-MR with a second control group. The primary end point was 6-month percent in-stent net volume obstruction measured by intravascular ultrasound. Secondary end points were 6-month angiographic restenosis and 6- and 12-month incidence of major adverse cardiac events, a composite of cardiac death, myocardial infarction, and repeat revascularization. At 6 months, percent net volume obstruction within the stent was significantly lower for TAXUS stents (7.9% SR and 7.8% MR) than for respective controls (23.2% and 20.5%; P<0.0001 for both). This corresponded with a reduction in angiographic restenosis from 17.9% to 2.3% in the SR cohort (P<0.0001) and from 20.2% to 4.7% in the MR cohort (P=0.0002). The incidence of major adverse cardiac events at 12 months was significantly lower (P=0.0192) in the TAXUS-SR (10.9%) and TAXUS-MR (9.9%) groups than in controls (22.0% and 21.4%, respectively), predominantly because of a significant reduction in repeat revascularization of the target lesion in TAXUS-treated patients. CONCLUSIONS: Compared with a bare metal stent, paclitaxel-eluting stents reduced in-stent neointimal formation and restenosis and improved 12-month clinical outcome of patients with single de novo coronary lesions.

Coated Materials, Biocompatible↗

Explicit relations between elastic and conductive properties of materials containing annular cracks.

The impact of annular cracks on the effective elastic and conductive properties of a material is analysed. The compliance contribution tensor of an annular crack - the quantity that determines the increase in compliance of a solid due to introduction of such a crack - is derived analytically. The resistivity contribution tensor of an annular crack is calculated numerically. It is shown that an effective circular crack, i.e. a crack which yields the same change in elastic/conductive properties of a material as the given annular crack, can be chosen to match both of these tensors. Using this result, the explicit relation between elastic and conductive properties of a material containing annular cracks is obtained. The relation is derived using a non-interaction approximation. Applicability of the derived formulae to real materials (to plasma-sprayed coatings, in particular) is discussed.

Coated Materials, Biocompatible↗