Techniques to maximize flexible ureteroscope longevity.

Abstract

OBJECTIVES: To assess methods to improve the longevity and durability of flexible ureteroscopes by using the ureteral access sheath, 200-microm holmium laser fiber, and nitinol baskets or graspers during routine ureteroscopic procedures. Despite adequate advances in fiberoptics and endoscope design, the decreased size of currently available flexible ureteroscopes makes damage inevitable after repeated use. However, new auxiliary tools may be able to enhance ureteroscope durability. METHODS: The indications for performing flexible ureteroscopy were proximal ureteral stones (n = 32), renal calculi (n = 59), treatment of upper tract transitional cell carcinoma (n = 3), evaluation of hematuria or filling defect (n = 7), and treatment of ureteral strictures or ureteropelvic junction obstruction (n = 8). Using four new 7.5F flexible ureteroscopes, we prospectively evaluated the number of passes of each ureteroscope until more than 20 optical fibers were broken, more than a 25 degrees loss of deflection in either direction had occurred, or the instrument sustained injury requiring repair by the manufacturer. RESULTS: One hundred nine flexible ureteroscopic procedures (average 27.5 procedures per instrument; range 19 to 34) were performed with the four new flexible ureteroscopes before being sent for repair. Adjuncts to reduce scope damage during these procedures were the use of the ureteral access sheath (n = 109), nitinol devices allowing lower pole stone retrieval (n = 27), and the 200-microm holmium laser fiber for stone fragmentation, tumor ablation, and incision of ureteropelvic junction/ureteral stenoses (n = 91). The average number of passes until more than 20 optical fibers were broken was 15.3 (range 12 to 20), until more than a 25 degrees loss of deflection occurred was 50.3 (range 42 to 66), or until the scope required repair was 66.7 (range 46 to 82). CONCLUSIONS: Flexible ureteroscopy will be used increasingly to manage upper urinary tract pathologic findings. Historically, the number of procedures performed before a flexible ureteroscope requires repair averaged 6 to 15. By incorporating the new ureteroscopic accessories, such as nitinol devices, a ureteral access sheath, and the 200-microm holmium laser fiber into common practice, one can reduce the strain on these fragile 7.5F endoscopes, thereby maximizing their longevity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Paul K Pietrow, Brian K Auge, Fernando C Delvecchio, Ari D Silverstein, Alon Z Weizer, David M Albala, Glenn M Preminger. 2002. Techniques to maximize flexible ureteroscope longevity.. https://doi.org/10.1016/s0090-4295(02)01948-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tip cooling effect and failure mechanism of field-emitting carbon nanotubes.

The cooling effect accompanying field electron emission has been considered for a single carbon nanotube (CNT) used as a field emission (FE) electron source. An improved model for the failure mechanism of field emitting CNTs has been proposed and validated. Our model predicts a maximum temperature (T-max) located at an interior point rather than the tip of the CNTs, and the failure of the CNT emitters tends to take place at the T-max point, inducing a segment by segment breakdown process. A combination of Joule heating and electrostatic force effect is proposed responsible for initiating the failure of the field emitting CNT and validated by in situ FE observation.

Equipment Failure↗

[Importance of an initial check-up for diagnostic radiology apparatus management].

The management of apparatus for diagnostic imaging is an important job for radiological technologists. In the last 10 years we have encountered 2227 malfunctions in 3652 days. We detected 163 cases at the initial check-up, which accounted for 7.3% of total cases. By performing an initial check-up, we detected one malfunction every 21 days and were able to keep the effects of mishaps to a minimum, prevent accidents, and obtain stable-quality images.

Equipment Failure↗