PubMed Health⌕ Search

PubMed · 12454523

Active microelectronic array system for DNA hybridization, genotyping and pharmacogenomic applications.

Abstract

Microelectronic arrays have been developed for DNA hybridization analysis of point mutations, single nucleotide polymorphisms, short tandem repeats and gene expression. In addition to a variety of molecular biology and genomic research applications, such devices will also be used for infectious disease detection, genetic and cancer diagnostics, and pharmacogenomic applications. These microelectronic array devices are able to produce defined electric fields on their surfaces that allow charged molecules and other entities to be transported to or from any test site or micro-location on the planar surface of the device. These molecules and entities include DNA, RNA, proteins, enzymes, antibodies and cells. Electronic-based molecule addressing and hybridization can then be carried out, where the electric field is now used to greatly accelerate the hybridization reactions that occur on the selected test sites. When reversed, the electric field can be used to provide an additional parameter for improved hybridization. Special low-conductance buffers have been developed that provide for the rapid transport of the DNA molecules and facilitate the electronic hybridization reactions under conditions that do not support hybridization. Important to the device function is the permeation layer that overcoats the underlying microelectrodes. Generally composed of a porous hydrogel material impregnated with attachment chemistry, this permeation layer prevents the destruction of analytes at the active microelectrode surface, ameliorates the adverse effects of electrolysis products on the sensitive hybridization and affinity reactions, and serves as a support structure for attaching DNA probes and other molecules to the array. The microelectronic chip or array device is incorporated into a cartridge package (NanoChip trade mark cartridge) that provides the electronic, optical, and fluidic interfacing. A complete instrument system (NanoChip trade mark Molecular Biology Workstation) provides a chip loader, fluorescent reader, computer control interface and data display screen. The probe loader component allows DNA probes or target molecules (polymerase chain reactions amplicons, genomic DNA, RNA, etc.) to be selectively addressed to the array test sites, providing the end-user with 'make your own chip' capabilities. The electronic hybridization can then be carried out and the chip analyzed using a fluorescent detector system. In addition to carrying out rapid, accurate and highly reliable genotyping (point mutations, single nucleotide polymorphisms, short tandem repeats), other future applications include gene expression analysis, or on-chip amplification, immunoassays and cell separation and selection. Smaller and more compact systems are also being designed for portable sample to answer and point of care diagnostics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ron Sosnowski, Michael J Heller, Eugene Tu, Anita H Forster, Ray Radtkey. 2002. Active microelectronic array system for DNA hybridization, genotyping and pharmacogenomic applications.. https://doi.org/10.1097/00041444-200212000-00001

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of GenoType MTBC with RFLP-PCR and multiplex PCR to identify Mycobacterium tuberculosis complex species.

The aims of the work presented here were to evaluate a commercial system based on DNA hybridization technology on nitrocellulose strips (GenoType MTBC; Hain Diagnostika, Nehren, Germany) for identifying Mycobacterium tuberculosis complex isolates to the species level and to compare the results with those obtained using the RFLP-PCR and multiplex PCR molecular techniques, biochemical tests and susceptibility testing. The commercial system correctly identified 102 of 103 (99.03%) strains studied, indicating it is capable of discriminating among the tuberculosis complex species.

DNA Probes↗

Microarray-in-a-tube for detection of multiple viruses.

BACKGROUND: The detection of multiple viruses is important for pathogenic diagnosis and disease control. Microarray detection is a good method, but requires complex procedures for multiple virus detection. METHODS: We developed a novel PCR assay, the microarray-in-a-tube system, which integrates multiple PCR processes and DNA microarrays for multiple virus detection. A 5 x 5 oligonucleotide microarray for detecting 4 respiratory tract viruses (severe acute respiratory syndrome-associated coronavirus, influenza A virus, influenza B virus, and enterovirus) with inner controls was arranged on the inner surface of a specially designed Eppendorf cap with a flat, optically transparent window. RESULTS: We were able to perform all detection processes in the encapsulated system without opening the cap. The 4 viruses were successfully amplified by one-step reverse transcription-PCR in the encapsulated tube. After the PCR process, the microarray-in-a-tube was inverted, and the fluorescence-labeled PCR products were directly hybridized on the microarray. Hybridization signals were obtained with an ordinary fluorescent microscope. The sensitivity of the system for virus detection reached 10(2) copies/microL. With the help of inner controls, the system provided reliable results without false negatives and false positives. CONCLUSIONS: The microarray-in-a-tube system is a rapid, labor-saving tool for multiple virus detection with several advantages, such as convenience, prevention of cross-contamination of the PCR products, and potential for multiple-gene detection.

DNA Probes↗