Interleaved pulsed MAMBA: a new parallel slice imaging method.

Abstract

A method of acquiring slices in parallel is described which uses interleaved sets of pulsed B(0) field coils to generate discrete regions of uniform field within the main magnetic field known as interleaved MAMBA (multiple acquisition micro B(0) array). Simulations of a number of coil designs were performed using the Biot-Savart law. A six-step coil was built and interfaced to a 0.17 T Niche MRI system and the field steps measured using an imaging technique. Measured field steps were in good agreement with the values predicted by simulation. The coil design was then scaled up by a factor of three, interfaced to a 1.5 T whole-body MRI system, and scans of the hands and arms of volunteers were acquired from up to four field steps using standard spin and gradient echo sequences. Images were also acquired simultaneously from two field steps with no frequency encode aliasing and one excitation. The one-dimensional interleaved pulsed MAMBA step field technique shows great promise for enabling many slices to be acquired simultaneously along the axis of the coil for rapid volumetric studies without the need for multiple shot Hadamard encoding. Extension of interleaved coil design to two or three dimensions is feasible, which could provide full spatial coverage combined with ultra-rapid data acquisition.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Martyn N J Paley, Kuan J Lee, James M Wild, Elspeth H Whitby, Paul D Griffiths. 2002. Interleaved pulsed MAMBA: a new parallel slice imaging method.. https://doi.org/10.1002/mrm.10311

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Simple anatomical measurements do not correlate significantly to individual peripheral nerve stimulation thresholds as measured in MRI gradient coils.

PURPOSE: To examine peripheral nerve stimulation (PNS) thresholds for normal human subjects in magnetic resonance imaging (MRI) gradient coils, and determine if observed thresholds could be predicted based on gross physiologic measurements. MATERIALS AND METHODS: PNS thresholds for 21 healthy normal subjects were measured using a whole-body gradient coil. Subjects were exposed to a trapezoidal echo-planar imaging (EPI) gradient waveform and the total change in gradient strength (DeltaG) required to cause PNS as a function of the duration of the gradient switching time (tau) were measured. Correlation coefficients and corresponding P values were calculated for the PNS threshold measurements against simple physiologic measurements taken of the subjects, including weight, height, girth, and average body fat percentage, in order to determine if there were any easily observable dependencies. RESULTS: No convincing correlations between threshold parameters and gross physiologic measurements were observed. CONCLUSION: These results suggest it is unlikely that a simple physiologic measurement of subject anatomy can be used to guide the operation of MRI scanners in a subject-specific manner in order to increase gradient system performance while avoiding PNS.

Echo-Planar Imaging↗

Quantitative imaging of magnetization transfer using an inversion recovery sequence.

A new imaging method has been developed for quantitatively measuring magnetization transfer (MT). It uses a simple inversion recovery sequence, although one with very short (milliseconds) inversion times, and thus can be implemented on clinical imaging systems with little modification to existing pulse sequences. The sequence requires an inversion pulse with a length much longer than T(2m) (typically 10 micros) and much shorter than T(2f) (typically tens of ms) and 1/k(mf) (typically tens of ms), where T(2m) and T(2f) are the transverse relaxation times of the immobile macromolecular and free water protons, respectively, and k(mf) is the rate of MT between these populations. The resultant NMR signal is sensitive to MT when this inversion pulse affects the mobile and immobile proton pools to different degrees and by appropriate analysis of the signals obtained for different inversion times, quantitative information can be derived on the macromolecular content and exchange rates within the sample. The method has been used in conjunction with echo planar imaging to produce maps of the spatial distribution of the macromolecular content and MT rate in cross-linked bovine serum albumin. Comparisons between this method and other quantitative MT techniques are discussed.

Echo-Planar Imaging↗