PubMed Health⌕ Search

PubMed · 12466217

Cortical columns: a multi-parameter examination.

Abstract

Columnar structure in the cerebral cortex has been demonstrated in numerous studies. However, in the visual system, it is not clear from imaging, basic physiological and anatomical approaches how multiple stimulus parameters are related within columns. We have analyzed recordings from pairs of neurons in the striate cortex of the cat using various spatial and temporal parameters. We find that most parameters are clustered within inferred columns with the exception of spatial phase. Diversity of phase could be useful for serial processing in central visual pathways.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ralph D Freeman. 2003. Cortical columns: a multi-parameter examination.. https://doi.org/10.1093/cercor%2F13.1.70

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Sensitivity of surface EMG-based conduction velocity estimates to local tissue in-homogeneities--influence of the number of channels and inter-channel distance.

The aim of this simulation study was to investigate the influence of local tissue in-homogeneities on the estimates of muscle fiber conduction velocity (CV) from surface EMG signals. A recently developed analytical surface EMG model was used to generate simulated surface EMG signals from a planar layered volume conductor, comprised of the muscle tissue and fat layer, with spheres (1 mm radius) in the fat layer of conductivity different from the surrounding tissue. CV was estimated with a maximum likelihood multi-channel approach, varying the number of channels and the inter-channel distance used for the estimate. The action potentials detected along the muscle fiber direction changed shape due to the presence of the in-homogeneities, thus affecting CV estimates. CV estimates were influenced by the location of the in-homogeneities with respect to the fiber and detection electrodes. The maximum percent variation of CV estimates due to the presence of in-homogeneities decreased with increasing number of channels and inter-channel distance: 19.6% (2 channels), 12.1% (3 channels), 6.4% (4 channels), for 5 mm inter-channel distance, and 12.0% (2 channels), 5.2% (3 channels), 2.4% (4 channels), for 10 mm inter-channel distance (for double differential detection). The results were in agreement and explained previous experimental findings. It was concluded that multi-channel methods for CV estimation significantly reduce the sensitivity of CV estimates to tissue in-homogeneities.

Action Potentials↗

Single neuronal recordings using surface micromachined polysilicon microelectrodes.

Bulk micromachining techniques of silicon have been used successfully in the past several years to microfabricate microelectrodes for monitoring single neurons in acute and chronic experiments. In this study we report for the first time a novel surface micromachining technique to microfabricate a very thin polysilicon microelectrode that can be used for monitoring single-unit activity in the central nervous system. The microelectrodes are 3 mm long and 50 microm x 3.75 microm in cross-section. Excellent signal to noise ratios in the order of 25-35 dB were obtained while recording neuronal action potentials. The microelectrodes successfully penetrated the brains after a microincision of the dura mater. Chronic implantation of the microprobe for up to 33 days produced only minor gliosis. Since the polysilicon shank acts as a conductor, additional processing steps involved in laying conductor lines on silicon substrates are avoided. Further, surface micromachining allows for fabricating extremely thin microelectrodes which could result in decreased inflammatory responses. We conclude that the polysilicon microelectrode reported here could be a complementary approach to bulk-micromachined silicon microelectrodes for chronic monitoring of single neurons in the central nervous system.

Action Potentials↗

An economical multi-channel cortical electrode array for extended periods of recording during behavior.

We report the development of a low-cost chronic multi-channel microwire electrode array for recording multi-unit cortical responses in behaving rodents. The design was motivated by three issues. First, standard connector systems tended to disconnect from the head-stage during extended periods of behavior. Disconnections resulted in a loss of data and an interruption of the animals' behavior. Second, the use of low insertion force connectors with locking mechanisms was cost prohibitive. Finally, connecting the head-stage to a skull-mounted connector on an unrestrained animal was highly stressful for both the researcher and animal. The design developed uses a high insertion force DIP socket separated from the skullcap that prevents inadvertent disconnects, is inexpensive, and simplifies connecting unrestrained rodents. Electrodes were implanted in layer IV of primary auditory cortex in 11 Sprague-Dawley rats. Performance of the electrodes was monitored for 6 weeks. None of the behaving animals became disconnected from the recording system during recording sessions lasting 6 h. The mean signal-to-noise ratio on all channels (154) following surgery was 3.9+/-0.2. Of the 154 channels implanted, 130 exhibited driven activity following surgery. Forty percent of the arrays continued to exhibit driven neural activity at 6 weeks.

Action Potentials↗