PubMed Health⌕ Search

PubMed · 12478092

Prostate biopsy: indications and technique.

Abstract

PURPOSE: The last decade has seen numerous modifications in the way prostate cancer is diagnosed. We review the current indications for and methods of prostate biopsy. MATERIALS AND METHODS: The English language literature was reviewed regarding major indications for and methods of prostate biopsy. Pertinent peer reviewed articles were collated and analyzed. RESULTS: The most widely accepted indication for prostate biopsy is a prostate specific antigen (PSA) value of greater than 4.0 ng./ml. However, some investigators advocate prostate biopsy for men with a PSA value in the 2.5 to 4.0 ng./ml. range, believing that use of this parameter results in detection of a greater number of cases of curable disease. Age specific PSA range, percent free PSA and presence of prostatic intraepithelial neoplasia or atypia are all considered to be relative indications for prostate biopsy. The current literature describes a trend toward increasing the number of cores obtained and the sites biopsied beyond those of the standard sextant technique. The additional cores in many series are obtained from more lateral regions of the gland. CONCLUSIONS: Although several criteria are used as indications for initial prostate biopsy, all are based on PSA level and/or abnormal digital rectal examination. Future improvements in currently used prostate cancer markers may result in better selection of cases to biopsy. There is no universally accepted technique of prostate gland biopsy. The current literature supports use of more extensive biopsy techniques to increase the likelihood of prostate cancer detection.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Brian R Matlaga, L Andrew Eskew, David L McCullough. 2003. Prostate biopsy: indications and technique.. https://doi.org/10.1016/s0022-5347(05)64024-4

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Targeting difficult accessible breast lesions: MRI-guided needle localization using a freehand technique in a 3.0 T closed bore magnet.

PURPOSE: To report the accuracy of magnetic resonance imaging (MRI)-guided needle localization for diagnosis of MRI detected suspicious breast lesions located in difficult accessible regions of the breast, using the freehand method in a 3.0 T closed bore magnet. MATERIALS AND METHODS: In five patients with five MRI-only breast lesions underwent MRI-guided needle localization for histopathologic evaluation of the lesions. All interventional procedures were performed in a 3.0 T MRI system with the patient in prone position and by using a dedicated phased array breast coil. MRI-guided needle localizations were performed by using a freehand technique. In our study, the high-resolution scan allowed preprocedural localization of all lesions without use of contrast enhancement. In all cases contrast-enhanced MRI was performed after insertion of the wire to confirm the tip of the wire in direct contact with the enhancing lesion. RESULTS: Needle localizations were performed in five patients. Histopathologic evaluation of tissue after surgery excision biopsy revealed one lymph node, three invasive ductal carcinoma and one ductal carcinoma in situ. Lesion size varied from 6 to 30 mm. Mean duration time was 25 min. No complications occurred during the intervention method. In the patient with the benign lesion control MRI of the breast after 6 months confirmed lesion removal. CONCLUSIONS: MRI-guided needle localization by using a freehand technique in a 3.0 T closed bore magnet is a safe and accurate method for diagnosis of difficult accessible breast lesions only visible on MRI.

Biopsy, Needle↗