PubMed Health⌕ Search

PubMed · 12495759

Temperature differences during sleep between fullterm and preterm neonates at matched post-conceptional ages.

Abstract

OBJECTIVE: Altered physiologic behaviors during sleep have been described for healthy preterm neonates at post-conceptional fullterm ages. These differences may reflect brain dysmaturity as a result of conditions of prematurity. The present study examines if differences in state-specific temperature changes exist in a healthy preterm cohort as another expression of brain dysmaturity. METHODS: Rectal and skin temperatures during sleep state transitions are reported in 59 asymptomatic post-conceptional age term infants, comparing 25 full term and 34 preterm infants. Three-hour 24-channel electroencephalogram (EEG)-sleep studies were recorded for each child. One of 4 sleep states were assigned for each of 7339 min, based on both cerebral and non-cerebral measures. For each study, average rectal and skin temperatures for each sleep state were calculated. Repeated measures MANOVA were performed using 4 explanatory variables, average skin and rectal temperatures and variance of rectal and skin temperatures, comparing preterm/fullterm status and 4 sleep states. RESULTS: Rectal temperature differences between neonatal cohorts during specific sleep states were noted: F=8.58, P<0.0001. Significant differences were noted for both average and variance of rectal temperatures during all 4 sleep states with higher temperatures in the preterm group. For all neonates, both skin and rectal temperature differences were also noted among sleep states (F=4.22, P<0.0004). Differences were specifically noted between two specific EEG segments, mixed frequency active sleep and tracé alternant quiet sleep (P<0.0004). CONCLUSIONS: In summary, significant differences in temperatures were noted across sleep state transitions for two neonatal cohorts, with higher average rectal temperatures in the preterm cohort. These findings highlight an altered measure of brain function during sleep in preterm infants affecting temperature regulation. This altered physiologic behavior reflects adaptation of the infant's brain function to conditions of prematurity which may contribute to vulnerabilities at older ages.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mark S Scher, Doris A Steppe, Dawn G Salerno, Marquita E Beggarly, David L Banks. 2003. Temperature differences during sleep between fullterm and preterm neonates at matched post-conceptional ages.. https://doi.org/10.1016/s1388-2457(02)00319-x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Thermographic assessment of inferior alveolar nerve injury in patients with dentofacial deformity.

PURPOSE: The purpose of this study was to evaluate the injury and recovery of the inferior alveolar nerve in orthognathic patients at 1 and 4 weeks after surgery using electronic thermography. MATERIALS AND METHODS: Twenty subjects with Class III dentofacial deformity were studied. All patients underwent bilateral sagittal split ramus osteotomy. To image the temperature of the face, 1 anteroposterior view and 1 lateral view were taken from both the right and left sides. Similar images were taken at 1 and 4 weeks after surgery. The control was the presurgical temperature of the 20 patients who showed unilateral or bilateral nerve damage after surgery. RESULTS: In the patients with unilateral nerve damage (n = 14), on the anteroposterior views, the temperatures of the mentum on the 2 sides differed by 0.64 degrees C at 1 week after surgery, and the difference decreased to 0.23 degrees C at 4 weeks after surgery. On the lateral images, the differences in temperature between the mentum areas were 0.10 degrees C at 1 week and 0.27 degrees C at 4 weeks after surgery. In the patients with bilateral nerve injury (n = 6), on the anteroposterior views, the temperatures of the mentum on the 2 sides differed by 0.20 degrees C at 1 week after surgery and 0.13 degrees C after 4 weeks. On the lateral views, the differences were 0.18 degrees C at 1 week and 0.34 degrees C at 4 weeks after surgery. Using the repeated measurement analysis method, the anteroposterior view showed statistically significant results in the patients with unilateral nerve damage. CONCLUSION: The infrared body temperature method is an objective method that can be applied as a supplemental diagnostic method for inferior alveolar nerve injury.

Body Temperature↗

The ingestible telemetric body core temperature sensor: a review of validity and exercise applications.

An ingestible telemetric temperature sensor for measuring body core temperature (Tc) was first described 45 years ago, although the method has only recently gained widespread use for exercise applications. This review aims to (1) use Bland and Altman's limits of agreement (LoA) method as a basis for quantitatively reviewing the agreement between intestinal sensor temperature (Tintestinal), oesophageal temperature (Toesophageal) and rectal temperature (Trectal) across numerous previously published validation studies; (2) review factors that may affect agreement; and (3) review the application of this technology in field-based exercise studies. The agreement between Tintestinal and Toesophageal is suggested to meet our delimitation for an acceptable level of agreement (ie, systematic bias <0.1 degrees C and 95% LoA within +/-0.4 degrees C). The agreement between Tintestinal and Trectal shows a significant systematic bias >0.1 degrees C, although the 95% LoA is acceptable. Tintestinal responds less rapidly than Toesophageal at the start or cessation of exercise or to a change in exercise intensity, but more rapidly than Trectal. When using this technology, care should be taken to ensure adequate control over sensor calibration and data correction, timing of ingestion and electromagnetic interference. The ingestible sensor has been applied successfully in numerous sport and occupational applications such as the continuous measurement of Tc in deep sea saturation divers, distance runners and soldiers undertaking sustained military training exercises. It is concluded that the ingestible telemetric temperature sensor represents a valid index of Tc and shows excellent utility for ambulatory field-based applications.

Body Temperature↗