PubMed Health⌕ Search

PubMed · 12559589

Oriented versus random protein immobilization.

Abstract

Immobilization of proteins on solid surfaces plays an important role in all the fields of modern biology. Two approaches are used in the immobilization of proteins: a random and an oriented mode of binding to solid matrices. In this note, we show that there is not much difference in using either mode of immobilization, since proteins usually bind to a matrix through only one or two bonds. This is demonstrated by the attachment of several proteins to CNBr-activated Sepharose through their lysines and the consequent conversion of those lysines to homoarginine upon treatment with ammonium hydroxide.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Meir Wilchek, Talia Miron. 2003-01-31. Oriented versus random protein immobilization.. https://doi.org/10.1016/s0165-022x(02)00178-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of two-step sol-gel reaction on the mesoporous silica structure.

In the present study, we investigated the effects of two-step sol-gel reaction by abrupt pH change on the SBA-15 and mesocellular silica foams (MCF). Mesoporous silica was fabricated by using triblock copolymer templates (poly(ethylene oxide) and poly(propylene oxide)). The prepared silica structure was characterized by X-ray diffraction, transmission electron microscopy, and N(2) sorption experiment. Specifically, we prepared SBA-15 with long-range two-dimensional hexagonal arrangement of 3 to 6-nm feature spacing and MCF with larger pores of a few tens of nanometers. The pore size and ordering were influenced by pH change in a two-step sol-gel reaction and the concentration of organic solvent. Although well-ordered hexagonal arrangement of mesopores was prevalent in acidic conditions, the materials synthesized by a single-step reaction in neutral or basic conditions possessed gel-like structure without mesopores. However, the present two-step reaction (low pH sol-gel reaction followed by high pH reaction) not only produced mesoporous materials but also provided controllability of the pore size. In particular, mesoporous structures with pore sizes as large as those of MCF were successfully fabricated by the two-step reaction without using organic swelling agents. As expected, when xylene was added as a swelling agent, the pore size increased with the xylene/copolymer weight ratio.

Ammonium Hydroxide↗

Microcapillary liquid chromatography/tandem mass spectrometry using alkaline pH mobile phases and positive ion detection.

Extending the dynamic range of microcapillary liquid chromatography/tandem mass spectrometry (LC/MS/MS) peptide sequencing methods is essential for extracting new discoveries from proteomic studies. The complexity of global protein digests and in vivo processed peptide repertoires (as isolated from immunologically important HLA complexes) have led to the development of novel separation methods to increase the number of peptides identified by a single analysis. Separation of complex mixtures by multidimensional high-performance liquid chromatography (HPLC) decreases the number of isolated peptides contained in each fraction and increases the likelihood of detecting low abundant peptides in a background of dominant signals. In this study, we have evaluated the use of two dimensions of reversed-phase chromatography for resolving and sequencing naturally processed HLA-A2 presented peptide repertoires. The first dimension of separation was reversed-phase chromatography using the strong ion pairing reagent trifluoroacetic acid (TFA) to ensure the highest efficiency of peptide fractionation. The second dimension of reversed-phase chromatography was online with an electrospray ionization (ESI) ion trap mass spectrometer. Mobile phases used for the second dimension of chromatography were modified with volatile reagents including a contemporary acetate-modified acidic solvent, which was compared with mobile phases prepared with ammonium hydroxide at an alkaline pH. As expected, we demonstrate improved separation of the HLA-A2 presented fractions using the alkaline pH conditions. However, less obvious was the improved peptide signal-to-noise detected for peptide signals by positive ion ESI ion trap mass spectrometric detection, which was attributed to a reduced chemical background when using the alkaline pH mobile phases that allowed the ion trap to fill with the peptide ions until the automatic gain control detected a full trap. The term 'wrong-way-round ionization' has been used to describe intense [M+H](+) ions generated during ESI under strongly basic solutions. Ultimately, a larger number of the HLA-A2 peptide repertoire was sequenced by coupling TFA-modified reversed-phase fractionation with alkaline-modified microcapillary LC/MS/MS analysis of each fraction. In the present report, we compare the two second-dimension approaches and demonstrate the quality of data that was acquired using alkaline pH reversed-phase conditions.

Ammonium Hydroxide↗

Ion chromatographic analysis of anions in ammonium hydroxide, hydrofluoric acid, and slurries, used in semiconductor processing.

In this study, ion chromatography (IC) with suppressed conductivity detection was used for the determination of trace anions in 29% (w/w) ammonium hydroxide, 49% (w/w) hydrofluoric acid and slurries. For these samples, various sample pretreatment methods were applied to eliminate matrix interferences. For concentrated ammonium hydroxide, an on-line electrochemical neutralizer (SP10 AutoNeutralization module) was used to neutralize the base prior to the IC analysis. For concentrated hydrofluoric acid, a heart cutting technique with an ion-exclusion column was used to separate the anions of interest prior to an IC separation. A method was also developed to analyze chloride in silica slurries by IC.

Ammonium Hydroxide↗