Abstract

In this study, we examine longitudinal aliasing properties in multislice helical computed tomography (CT) volumes reconstructed under the multiple parallel fanbeam approximation by use of a 180LI-type algorithm. We focus on the differences between the multislice case and the single-slice case, which has been studied previously. Specifically, we examine longitudinal aliasing properties in four-slice scanners for helical pitches 3 and 6, which are sometimes called "preferred" in four-slice helical CT, because it is believed that the effective longitudinal sampling intervals at these pitches are equivalent to those in single-slice helical CT operating at pitches 1 and 2, respectively. While these equivalences have been supported by comparative studies of slice-sensitivity profiles in single- and multislice helical CT, artifacts have been observed in pitch-3 and pitch-6 multislice images that were not evident in their purported single-slice counterparts. We attribute these differences to aliasing arising in the multislice reconstructions that is not present in the single-slice counterparts. We find that the aliasing has two principal origins: sampling effects similar to those in the single-slice case and cone-beam effects. The difference between the multislice, pitch-3 and single-slice, pitch-1 results is attributed to the small cone angle in multislice helical CT, which introduces inconsistencies among the measurements of different detector rows. The difference between multislice, pitch-6 and single-slice, pitch-2 results is attributed to a combination of the cone angle and genuine differences in sampling patterns. It is argued, however, that the lack of strict equivalence with single-slice counterparts does not necessarily undermine the claim that pitches 3 and 6 are "preferred" relative to other pitches in multislice helical CT.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Patrick J La Rivière, Xiaochuan Pan. 2002. Longitudinal aliasing in multislice helical computed tomography: sampling and cone-beam effects.. https://doi.org/10.1109/tmi.2002.806428

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗