A graphical object display improves anesthesiologists' performance on a simulated diagnostic task.

Abstract

OBJECTIVE: This study tests the hypothesis that a graphical object display (a data display consisting of meaningful shapes) will affect the ability of anesthesiologists to perform a diagnostic task rapidly and correctly. The diagnostic tasks studied were recognition and differentiation of five etiologies of shock--anaphylaxis, bradycardia, myocardial ischemia, hypovolemia, pulmonary embolus. METHODS: Data sets consisting of HR, Systemic Arterial BP, Pulmonary Arterial BP, CVP, and Cardiac Output were generated for five shock states and five non-shock states. The resulting 10 data sets were presented on a computer monitor to study subjects twice (first in an alpha-numeric format and then in the object format) for a total of twenty decision screens. Subjects used soft-buttons on a computer touch-screen monitor to: a) advance to the next display; b) differentiate a non-shock state from a shock state; and, c) select the etiology of shock state represented by the display (Figure 2). Data collection was automatic, using the internal clock and memory of the computer. RESULTS: Eleven anesthesiologists participated in this study. They completed a total of 3060 diagnostic decisions, half with each display format. Performance measures were time to decision and diagnostic accuracy. The object display improved no-shock recognition by 1.0 second and shock etiology determination by 1.4 seconds (p < 0.05). The object display also significantly improved accuracy for shock recognition by 1.4% and etiology determination by 4.1% (p < 0.05). Testing was completed in a time interval of <45 min per 10 trials. CONCLUSIONS: The primary finding of this study was that anesthesiologists using the object display format committed significantly fewer diagnostic errors when interpreting physiologic data. In addition, both the recognition of no-shock and the diagnosis of shock etiology were completed more rapidly when the object display was used. The major limitation of this initial trial is the simplicity of the test. Future investigation of the impact of the display on clinical decision making will require more realistic clinical scenarios with partial or full simulation to better understand the potential clinical impact.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G T Blike, S D Surgenor, K Whalen. 1999. A graphical object display improves anesthesiologists' performance on a simulated diagnostic task.. https://doi.org/10.1023/a%3A1009914019889

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Perception of training needs and opportunities in advanced airway skills: a survey of British and Irish trainees.

BACKGROUND AND OBJECTIVE: We surveyed delegates at the Group of Anaesthetists in Training (UK) meeting to investigate evidence of a training-gap (number of fibreoptic intubations believed to bestow competence vs. number actually performed). METHODS: Questionnaires were distributed to and collected from delegates in person. Questions covered six areas, including experience of fibreoptic intubation and cricothyrotomy, fibreoptic intubation as a specialist skill and ethical issues. RESULTS: We received 221 replies (76%). All trainees believed competence to be achievable with 10 intubations (interquartile range (IQR) 10-20); the median number performed was 2 (IQR 0-4). This was statistically significant for the groups' senior house officers, 1st and 2nd year registrars and 3rd and 4th year registrars; P < 0.0001. Many final year trainees (12/20, 60%) also failed to achieve their competency target. Few trainees had seen or performed any cricothyrotomies (medians 0, IQRs 0-1 and 0-0). Most (195/208, 94%) believed that fibreoptic intubation was a core skill and 199/212 (94%) believed that all should be competent by completion of training. Ten percent (n = 208) felt it unethical to perform an awake training intubation with full consent and 10% believed it acceptable without explanation. Most (82.7%) would fibreoptically intubate an asleep patient (requiring intubation) without consent. CONCLUSION: Trainees reported a gap between their perception of competence and achievement in awake fibreoptic intubation. Simple and complex simulations and structured training programmes may help. Anaesthetists must address the ethics of clinical training in advanced airway management.

Anesthesiology↗