PubMed · 12608356
13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 micrometers.
Abstract
A portable modular gas sensor for measuring the 13C/12C isotopic ratio in CO2 with a precision of 0.8%(+/-1 sigma) was developed for volcanic gas emission studies. This sensor employed a difference frequency generation (DFG)-based spectroscopic source operating at 4.35 micrometers (approximately 2300 cm-1) in combination with a dual-chamber gas absorption cell. Direct absorption spectroscopy using this specially designed cell permitted rapid comparisons of isotopic ratios of a gas sample and a reference standard for appropriately selected CO2 absorption lines. Special attention was given to minimizing undesirable precision degrading effects, in particular temperature and pressure fluctuations.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
M Erdelyi, D Richter, F K Tittel. 2002. 13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 micrometers.. https://doi.org/10.1007/s00340-002-0960-2