PubMed Health⌕ Search

PubMed · 12612674

Encoding microcarriers by spatial selective photobleaching.

Abstract

Bead-based assays on very large numbers of molecules in gene expression studies, drug screening and clinical diagnostics, require the encoding of each of the microspheres according to the particular ligand bound to its surface. This allows mixing the uniquely encoded microspheres and subjecting them to an assay simultaneously. When a particular microsphere gives a positive reaction, the substance on its surface can be identified by reading the code. Previously reported techniques for colour encoding polymer microspheres only allow for a limited number of unique codes. Graphical encoding methods use metallic particles, which are rather uncommon in screening applications. Here, we demonstrate a new approach to encode polymer microspheres that are commonly used in screening applications, such as polystyrene microspheres, with a method that provides a virtually unlimited number of unique codes. Patterns can be written in fluorescently dyed microspheres by 'spatial selective photobleaching' and can be identified by confocal microscopy. Such encoded microparticles can find broad application in the collection and analysis of genetic information, high-throughput screening, medical diagnostics and combinatorial chemistry, and can also be used for labelling of consumer goods or as security labels to prevent counterfeiting.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kevin Braeckmans, Stefaan C De Smedt, Chris Roelant, Marc Leblans, Rudi Pauwels, Joseph Demeester. 2003. Encoding microcarriers by spatial selective photobleaching.. https://doi.org/10.1038/nmat828

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Influence of particles on the transition to turbulence in pipe flow.

We investigate by experiment the influence of suspended solids upon the transition to turbulence in pipe flow. The particles are monodisperse and neutrally buoyant with the liquid. The role of the particles on the transition depends upon both the volume fraction, phi, and particle size. Below a critical particle diameter, particles alter the transition to larger critical Reynolds numbers for all phi. In contrast to this, larger particles move the transition to smaller Reynolds numbers for small phi, but they delay the transition at larger concentration.

Microspheres↗

Peptides with selective affinity for carbon nanotubes.

Because of their extraordinary electronic and mechanical properties, carbon nanotubes have great potential as materials for applications ranging from molecular electronics to ultrasensitive biosensors. Biological molecules interacting with carbon nanotubes provide them with specific chemical handles that would make several of these applications possible. Here we use phage display to identify peptides with selective affinity for carbon nanotubes. Binding specificity has been confirmed by demonstrating direct attachment of nanotubes to phage and free peptides immobilized on microspheres. Consensus binding sequences show a motif rich in histidine and tryptophan, at specific locations. Our analysis of peptide conformations shows that the binding sequence is flexible and folds into a structure matching the geometry of carbon nanotubes. The hydrophobic structure of the peptide chains suggests that they act as symmetric detergents.

Microspheres↗

Multivariate calibration models for lysozyme from near-infrared transmission spectra in scattering solutions of monodisperse microspheres.

The ability to quantify lysozyme is demonstrated for a series of aqueous samples with different degrees of scattering. Near-infrared spectra are collected for two sets of lysozyme/scattering solutions. In both sets of samples, the solutions are composed of lysozyme dissolved in acetate buffer with suspended monodisperse latex microspheres of polystyrene. The diameter of the microspheres is 6.4 microm for the first set and 0.6 microm for the second. For each set, the amount of microspheres range from 0.005 to 0.998 wt %, the lysozyme concentrations range from 0.834 to 28.6 mg/mL, and solution compositions are designed to minimize correlations between the concentration of lysozyme and percentage of microspheres. Near-infrared spectra are collected individually for each set of solutions. Single-beam spectra are collected over the combination spectral range (5000-4000 cm(-1), 2.0-2.5 microm) by transmitting the incident radiation through a 1.5-mm-thick sample that is maintained at 21 degrees C. Partial least-squares calibration models are evaluated individually for each data set both with and without wavelength optimization. Results indicate that models from raw, nonmodified, single-beam spectra are incapable of extracting lysozyme concentration from these highly scattering solutions. Accurate concentration measurements are possible, however, by implementing either a multiplicative scatter correction to the single-beam spectra or by taking the ratio of these single-beam spectra to an appropriate reference spectrum. In addition, digital Fourier filtering of these spectra enhances model performance. The best calibration model in the presence of 6.4-microm microspheres is obtained from multiplicative scatter corrected single-beam spectra over the 4550-4190-cm(-1) spectral range. The mean percent error of prediction (MPEP) and standard error of prediction (SEP) for this model are 2.2% and 0.28 mg/mL, respectively. Likewise, the multiplicative scatter corrected spectra with wavelength optimization provided the best calibration model for the 0.6-microm data set. In this case, the MPEP and SEP are 2.3% and 0.44 mg/mL, respectively. In addition, the ability to predict lysozyme concentrations is evaluated for the situation where the degree of scattering is greater in the predication samples compared to the calibration samples. Differences in the prediction ability are noted between the 6.4- and 0.6-microm data sets.

Microspheres↗