PubMed Health⌕ Search

PubMed · 12622146

Fluorescence-sensing methods.

Abstract

Novel approaches to sensor design, based on the use of an internal standard with appropriate spectral properties, provide new possibilities for designing simple devices for fluorescence sensing. Detection of combined emission from the reference and an analyte-sensitive fluorophore has been achieved in numerous measurements in cuvettes, tissues, and high-throughput formats. These methods have been used with a long-lifetime reference to measure pH, O2, pCO2, glucose, and calcium by means of modulation-sensing methods as well as by the use of oriented films as the reference for polarization sensing of glucose, pH, oxygen, and lactate. Polarization sensing has also been developed with visual detection to measure the concentration of rhodamine B and pH. Modulation and polarization sensing was found to be effective in highly scattering media such as Intralipid or tissue. The applicability of these technologies to transdermal diagnostics depends on the availability of red fluorophores that can be used in vivo. One dye that could possibly be used is indocyanine green (IcG), which absorbs and emits at wavelengths above 700 nm. Furthermore, IcG has already been approved for use in humans for monitoring burn severity and it has been detected through the skin. It appears likely that modern optics and electronic technology will allow the development of practical devices for biomedical use as shown in Scheme 1.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zygmunt Gryczynski, Ignacy Gryczynski, Joseph R Lakowicz. 2003. Fluorescence-sensing methods.. https://doi.org/10.1016/s0076-6879(03)60106-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Engineering asymmetric vesicles.

Vesicles are bilayers of lipid molecules enclosing a fixed volume of aqueous solution. Ubiquitous in cells, they can be produced in vitro to study the physical properties of biological membranes and for use in drug delivery and cosmetics. Biological membranes are, in fact, a fluid mosaic of lipids and other molecules; the richness of their chemical and mechanical properties in vivo is often dictated by an asymmetric distribution of these molecules. Techniques for vesicle preparation have been based on the spontaneous assembly of lipid bilayers, precluding the formation of such asymmetric structures. Partial asymmetry has been achieved only with chemical methods greatly restricting the study of the physical and chemical properties of asymmetric vesicles and their use in potential applications for drug delivery. Here we describe the systematic engineering of unilamellar vesicles assembled with two independently prepared monolayers; this process produces asymmetries as high as 95%. We demonstrate the versatility of our method by investigating the stability of the asymmetry. We also use it to engineer hybrid structures comprised of an inner leaflet of diblock copolymer and an independent lipid outer leaflet.

Fluorescence↗

Fluorescence diagnosis: a novel method to guide radical inguinal lymph node dissection in penile cancer.

In penile cancer there is still a diagnostic dilemma between over treatment of lymph node-negative patients and the missing of occult metastases by watchful waiting. In the current study the value of fluorescence diagnosis during radical inguinal lymph node dissection was evaluated. Five patients with penile cancer were elected to undergo groin dissection. All patients received 5-aminolevulinic acid (5-ALA) orally before the operation for fluorescence diagnosis. Intraoperatively, fluorescence detection of the lymph nodes was performed by visual detection and spectroscopy. Two of the five patients had positive inguinal lymph nodes. Fluorescence in tumor-bearing tissue was detectable in the exposed lymph nodes. Protoporphyrin IX (PPIX) is accumulated in tumor-positive lymph nodes, making fluorescence diagnosis in penile cancer possible. More studies with higher patient numbers are necessary to evaluate optimal dosage and excitation conditions to detect tumor-bearing nodes in vivo.

Fluorescence↗