PubMed Health⌕ Search

PubMed · 12627409

Kullback-Leibler divergence for evaluating bioequivalence.

Abstract

In this paper we propose a methodology for evaluating the bioequivalence of two formulations of a drug that encompasses not only average bioequivalence (ABE), but also the more recently introduced measures of population bioequivalence (PBE) and individual bioequivalence (IBE). The latter two measures are concerned with prescribability (PBE) and switchability (IBE). The main idea is to use the Kullback-Leibler divergence (KLD) as a measure of discrepancy between the distributions of the two formulations. Two formulations are declared bioequivalent if the upper bound of a level-alpha confidence interval for the KLD is less than a given goalpost to be set by a regulator. This new methodology overcomes many of the disadvantages of the corresponding measures recommended by the FDA. In particular the KLD: (i) possesses the natural hierarchical property that IBE => PBE => ABE; (ii) satisfies the properties of a true distance metric; (iii) is invariant to monotonic transformations of the data; (iv) generalizes easily to the multivariate case where equivalence on more than one parameter (for example, AUC, C(max) and T(max)) is required; and (v) is applicable over a wide range of distributions of the response variable (for example, those in the exponential family). The performance of the KLD relative to the metric proposed in guidance by the FDA for the evaluation of individual bioequivalence is evaluated using a simulation study. Previously published retrospective analyses using the FDA-proposed metric are contrasted with those based on the KLD. It is concluded that the KLD is a viable alternative to the FDA-proposed metric and that its mathematical and statistical properties make it a readily interpretable measure of the differences between formulations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Vladimir Dragalin, Valerii Fedorov, Scott Patterson, Byron Jones. 2003-03-30. Kullback-Leibler divergence for evaluating bioequivalence.. https://doi.org/10.1002/sim.1451

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Smooth semiparametric receiver operating characteristic curves for continuous diagnostic tests.

We propose a semiparametric kernel distribution function estimator, based on which a new smooth semiparametric estimator of the receiver operating characteristic (ROC) curve is constructed. We derive the asymptotic bias and variance of the newly proposed distribution function estimator and show that it is more efficient than the traditional non-parametric kernel distribution estimator. We also derive the asymptotic bias and variance of our new ROC curve estimator and show that it is more efficient than the smooth non-parametric ROC curve estimator proposed by Zou et al. (Stat. Med. 1997; 16:2143-2156) and Lloyd (J. Am. Stat. Assoc. 1998; 93:1356-1364). For our proposed estimators, we derive data-based methods for bandwidth selection. In addition, we present some results on the analysis of two real data sets. Finally, a simulation study is presented to show that our estimators are better than the non-parametric counterparts in terms of bias, standard error, and mean-square error.

Area Under Curve↗

Redox potential measurement as a rapid method for microbiological testing and its validation for coliform determination.

The redox potential is one of the most complex indicators of the physiological state of microbial cultures and its measurement could be a useful tool for the qualitative and quantitative determination of the microbial contamination. During the bacterial growth, the redox potential of the medium decreases. The shape of the redox potential curve is characteristic on the type of microorganism, and the rate of the change (dE/dt) is proportional to the living cell concentration. Defining the time required to reach a significant change in redox potential as Time to Detection (TTD), similarly to the impedimetric measurements, a strict linear correlation could be established between the TTD and the logarithm of the initial concentration of microorganisms. On the base of this calibration curve, the determination of living cell concentration could be simplified. For the experiments, a computer-controlled multi-channel measuring system and software was developed by the authors. The redox potential measurement method was tested and validated for the determination of coliform bacteria. The results have proved the high efficiency and reliability of the new method.

Area Under Curve↗

Determination of N-methyl-4-isoleucine-cyclosporin (NIM811) in human whole blood by high performance liquid chromatography-tandem mass spectrometry.

A liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the determination of N-methyl-4-isoleucine-cyclosporin (NIM811) was developed and validated over the concentration range 1-2500 ng/mL in human whole blood using a 0.05 mL sample volume. NIM811 and the internal standard, d(12)-cyclosporin A (d(12)-CsA), were extracted from blood using MTBE via liquid-liquid extraction. After evaporation of the organic solvent and reconstitution, a 10 microL aliquot of the resulting extract was injected onto the LC-MS/MS system. Chromatographic separation of NIM811 and internal standard was performed using a Waters Symmetry RP-8 (50 x 4.6 mm, 3 microm particle size) column. The mobile phase consists of 10 mm ammonium acetate in water (A) and acetonitrile (B), with 45% B from 0 to 0.2 min, 45 to 85% B from 0.2 to 0.8 min and 85% B from 0.8 to 2.2 min. The total run time was 3.5 min with a flow rate of 0.8 mL/min. The method was validated for sensitivity, linearity, reproducibility, stability, dilution integrity and recovery. The precision and accuracy of quality control samples at low (2.00 ng/mL), medium (20.0 and 400 ng/mL) and high (2000 ng/mL) concentrations were in the range 1.1-4.3% relative standard deviation (RSD) and -2.5-10.0% (bias), respectively, from three validation runs. The method has been used to measure the exposure of NIM811 in human subjects.

Area Under Curve↗