PubMed Health⌕ Search

PubMed · 12656283

Ground water model calibration using pilot points and regularization.

Abstract

Use of nonlinear parameter estimation techniques is now commonplace in ground water model calibration. However, there is still ample room for further development of these techniques in order to enable them to extract more information from calibration datasets, to more thoroughly explore the uncertainty associated with model predictions, and to make them easier to implement in various modeling contexts. This paper describes the use of "pilot points" as a methodology for spatial hydraulic property characterization. When used in conjunction with nonlinear parameter estimation software that incorporates advanced regularization functionality (such as PEST), use of pilot points can add a great deal of flexibility to the calibration process at the same time as it makes this process easier to implement. Pilot points can be used either as a substitute for zones of piecewise parameter uniformity, or in conjunction with such zones. In either case, they allow the disposition of areas of high and low hydraulic property value to be inferred through the calibration process, without the need for the modeler to guess the geometry of such areas prior to estimating the parameters that pertain to them. Pilot points and regularization can also be used as an adjunct to geostatistically based stochastic parameterization methods. Using the techniques described herein, a series of hydraulic property fields can be generated, all of which recognize the stochastic characterization of an area at the same time that they satisfy the constraints imposed on hydraulic property values by the need to ensure that model outputs match field measurements. Model predictions can then be made using all of these fields as a mechanism for exploring predictive uncertainty.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John Doherty. Ground water model calibration using pilot points and regularization.. https://doi.org/10.1111/j.1745-6584.2003.tb02580.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Size-exclusion chromatography-a review of calibration methodologies.

Recent developments are reviewed in size exclusion chromatographic calibration methodologies, including direct calibration by using narrow and broad polymer standards and various instrumental methods (nuclear magnetic resonance, mass spectrometry, light scattering) as well as universal calibration with and without viscometry detectors, for simple and complex polymers.

Calibration↗

A mini-rapid-scan-spectrophotometer.

The mini-rapid-scan-spectrophotometer (Mini-RSS) is a scanning single-beam spectrophotometer that has been patented. It is based on a minimum of reflections and involves exclusively mirrors as beam-deflecting components. This way stray light is minimized, which results in an excellent light-throughput, high dynamics, low cost, compactness and rigidity. The Mini-RSS has been designed as a multi-purpose instrument that allows absorption, transmission, reflection, fluorescence and luminescence measurements in a single-beam mode. Its spectral range extends from the UV and visible spectrum to the IR. This provides for the possibility to measure even optically unfavorable, highly turbid or scattering samples that would be otherwise inaccessible to investigations with commercial spectrophotometers. A miniaturized and very sensitive photomultiplier-module (PM) of high dynamics allows in the visible spectral range absorbance measurements that cover up to four OD units. The Mini-RSS is capable of scanning up to 100 spectra per second with a resolution of 12 bit and 500 points. The linear dispersion is currently 5 nm and the stray light level <0.01%.

Calibration↗

Rapid spectrofluorimetric determination of lisinopril in pharmaceutical tablets using sequential injection analysis.

The present work reports for the first time a simple and rapid method for the spectrofluorimetric determination of lisinopril (LSP) in pharmaceutical formulations using sequential injection analysis (SIA). The method is based on reaction of LSP with o-phthalaldehyde (OPA) in the presence of 2-mercaptoethanol (borate buffer medium, pH=10.6). The emission of the derivative is monitored at 455 nm upon excitation at 346 nm. The various chemical and physical conditions that affected the reaction were studied. The calibration curve was linear in the range 0.3-10.0 mg L(-1) LSP, at a sampling rate of 60 injections h(-1). Consumption of OPA reagent was significantly reduced compared with conventional flow injection (FI) systems, because only 50 microL of OPA was consumed per run. The method was found to be adequately precise ( s(r)=2% at 5 mg L(-1) LSP, n=10) and the 3 sigma detection limit was 0.1 mg L(-1). The method was successfully applied to the analysis of two pharmaceutical formulations containing LSP. The results obtained were in good agreement with those obtained by use of high-performance liquid chromatography (HPLC), because the mean relative error, e(r), was <1.8%.

Calibration↗