PubMed Health⌕ Search

PubMed · 12679859

Observing bacterial activity interferometrically.

Abstract

It is shown that bacterial activity, even of slowly growing species, can be detected by precise interferometric measurements of refractive index changes of the culture medium. The bacteria-containing sample is kept in an isothermal block together with a reference liquid without bacteria. The biological activity is obtained from the difference of the index changes of these samples. Experiments were performed with Bacilo Calmette-Guérin. The order of magnitude of the observed total refractive index change was compatible with theoretical estimates based on the amount of available oxygen. An unexpected positive index change during the lag phase was observed, which might permit fast diagnostics in medical applications. This technique may provide cheap and quick tests of bacterial susceptibility with respect to antibiotics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Faragó Jardim, R Batista Santiago Neto, R R P Machado, F M Aarestrup, J P R F de Mendonça, B Lesche. 2003-03-22. Observing bacterial activity interferometrically.. https://doi.org/10.1007/s00249-003-0288-9

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

High-speed adaptive interferometer for optical coherence-domain reflectometry through turbid media.

Two-wave mixing in a dynamic holographic film acts as the adaptive beam combiner in a short-coherence interferometer that performs optical coherence-domain reflectometry (OCDR) through turbid media. This approach combines the high spatial resolution and sensitivity of coherence-domain reflectometry with photorefractive quantum-well-based adaptive homodyne detection. A depth resolution of 28 microm and penetration through 16 mean free paths in a turbid medium have been obtained in this adaptive OCDR application.

Interferometry↗

Delay and dispersion characteristics of a frequency-domain optical delay line for scanning interferometry.

The reflective frequency-domain optical delay line employing a diffraction grating, a lens, and a tiltable mirror has emerged as a device particularly suitable for interferometry and optical coherence tomography. The device is comprehensively described, both theoretically and experimentally, in the context of interferometry. The variations of phase and group delay produced by the device as well as its dispersive properties are described and demonstrated experimentally.

Interferometry↗

Interferometric measurement of the refractive-index distribution in plastic lenses by use of computed tomography.

A nondestructive measurement method that makes possible the measurement of a three-dimensional refractive-index distribution of any shape plastic lens is presented. In this method, a Mach-Zehnder interferometer and shearing interferometer are combined into a single optical system and are used selectively. Interference fringes of a test object that is immersed in matching liquid are detected at various rotation angles. And transmitted wave fronts are calculated with these interference fringes. Finally, the refractive-index distribution is obtained by computed tomography analysis. In addition, accurate control of the matching liquid temperature makes it possible to measure the absolute refractive index of the test object. This system has good performance with a measurement accuracy of 10(-4) or better peak to valley.

Interferometry↗