Matching point clouds: limits and possibilities.

Abstract

In computer-aided production of fixed dental restorations, the process chain always starts with digitizing, independent of the type of further (data) processing, the material used, and the kind of restoration to be produced. The quality of the digitized data, followed by the influences of further data processing and the production parameters, decisively influence the fitting accuracy of the dental restoration to be fabricated. The accuracy with which individually measured 3D data sets in the form of point clouds can be matched for further processing in one common system of coordinates was the object of the present study. Casts of the maxilla and mandible were digitized in several partial measurements comprising two to three teeth in each case, using an optical three-coordinate measuring system. The individual segments were sequentially aligned to surfaces that were created on the basis of partial point clouds. The mean deviation between surfaces and point clouds was between 1.90 microns and 18.24 microns. The accuracy of the alignment was determined by the RMS (root mean square) error, and was on average 14.2 microns (SD 7 microns) for the maxilla and 17.2 microns (SD 9.4 microns) for the mandible. Combining a larger number of smaller segments did not improve the result, since the errors of the individual registrations are summed in sequential matching. In this study, the errors arising in matching are not negligible and can possibly negatively influence the quality (fitting accuracy) of the restoration produced on the basis of the matched data records.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H Rudolph, S Quaas, R G Luthardt. Matching point clouds: limits and possibilities.. https://pubmed.ncbi.nlm.nih.gov/12680049/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A system for logging incontinence events using a simple disposable sensor.

Many elderly people entering residential or nursing care are already incontinent to some degree, relying on incontinence pads to deal with the consequences. A proportion of these people have been shown to exhibit a regular pattern in their incontinence, which opens up the possibility of mitigating the problem by instituting an individual toileting regime for the person. This can reduce their reliance on incontinence pads, both improving their quality of life, and reducing the cost of care. This paper covers the development and evaluation of a sensor for detecting incontinence events, suitable for use in this setting, and describes the design of an associated electronic logger. The devices form part of an assessment system intended to identify a pattern in incontinence where it exists, and to help with the design of the toilet regime for an individual. The requirement is that the system must reliably record incontinence events, and present the information describing them in a manner appropriate to the users of the devices, who are likely to be non-technical and non-specialist.

Analog-Digital Conversion↗

Issues in using databases of pre-recorded physiological signals to test medical devices.

Bench testing with databases of pre-recorded physiological signals is a common step in the verification and validation of medical devices. For example, in the case of an electrocardiographic (ECG) monitor to be tested, the physiological signals are ECG tracings that have previously been recorded from patients using other ECG monitors. Human overreaders then annotate the tracings to determine the occurrence of significant clinical events such as ventricular tachycardia. These annotations can be used to determine the sensitivity and specificity of the ECG monitor to be tested. This article aims to highlight some issues associated with such bench testing, such as the way the pre-recorded signals are presented to the medical device to be tested, the adequacy of single channel versus dual channel versus multi-channel testing in the bench testing, and the need for the human overreaders and the medical device to use the same set of rules for determining the occurrence of a clinical event. These issues are also applicable to other monitors such as the apnea monitor. Some suggestions for addressing the issues are presented.

Analog-Digital Conversion↗