PubMed Health⌕ Search

PubMed · 12685608

Solid-phase extraction and sample stacking-micellar electrokinetic capillary chromatography for the determination of multiresidues of herbicides and metabolites.

Abstract

Micellar electrokinetic capillary chromatography (MEKC) with diode array detection was used for the separation of 13 compounds (eight herbicides widely used in agriculture: metribuzin, lenacil, ethofumesate, atrazine, terbutryn, isoproturon, chlorotoluron and linuron, and five of their principal degradation products; namely, deethylatrazine, 2-hydroxyatrazine, deethyl-2-hydroxyatrazine, deisopropylatrazine and 3-chloro-4-methylphenylurea). Peak separation for the 13 analytes was not successful when a single surfactant system was employed, neither sodium dodecyl sulfate (SDS) nor dioctyl sulfosuccinate (DOSS) sodium salt. However, a mixture of these herbicides was successfully separated using a mixed micellar system involving SDS-DOSS in less than 14 min. An application study of an on-line concentration technique for MEKC was carried out to enhance sensitivity. The optimized on-line stacking procedure consisted simply of the addition of 50 mM of sodium chloride to the injection sample, the stacking effect being more intensive as analyte polarity increased. When this stacking procedure was combined with an off-line sample preconcentration step, based on solid-phase extraction, analytes could be detected in the ppb range. The whole method was applied to ultra-high-quality and natural waters. Linear relationships between the analytical signal and the initial analyte concentration were found to be independent of the type of water, except for the more polar analytes for which small differences were observed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Carabias-Martínez, E Rodríguez-Gonzalo, P Revilla-Ruiz, J Domínguez-Alvarez. 2003-03-21. Solid-phase extraction and sample stacking-micellar electrokinetic capillary chromatography for the determination of multiresidues of herbicides and metabolites.. https://doi.org/10.1016/s0021-9673(02)01969-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Enzyme assay for protein kinase using micellar electrokinetic chromatography with laser-induced fluorescence detection.

Micellar electrokinetic chromatography (MEKC) with laser-induced fluorescence (LIF) detection has been developed for a protein kinase assay. This protein kinase assay could readily determine the phosphorylation activity of substrate peptide kemptide using cAMP-dependent protein kinase (PKA) as a model enzyme. Kemptide and phosphorylated kemptide could be reacted with 7-fluoro-4-nitrobenzo-2-oxa-1,3-diazole (NBD-F) as a fluorescence derivatization reagent for LIF detection by directly adding NBD-F into the PKA enzymatic reaction mixture. These derivatives of substrate and product were separated and detected within the analysis time of 5 min by micellar electrokinetic mode using a mixture of sodium dodecylsulfate and methanol as a running buffer. Good linearity of the peak response of the phosphorylated kemptide was obtained over the range of 1-20 mU/tube of PKA in the assay. The relative standard deviation of the peak areas of the phosphorylated kemptide using 2, 5 and 10 mU/tube of PKA were calculated to <10.4%, indicating that the assay was reproducible. Also, IC(50) values of six PKA inhibitors, the K(i) value and the inhibition pattern of one inhibitor, which were calculated to estimate by the variation of the peak area of the phosphorylated kemptide using 5 mU/tube of PKA, were consistent with the published data. The sensitivity of the assay was higher than that of enzyme-linked immunosorbent assay (ELISA) for PKA phosphorylation activity, as IC(50) values, K(i) value, and the inhibition mechanism of inhibitors could be estimated using one-tenth amounts of PKA, compared with that of ELISA. The MEKC-LIF is expected to be very useful for protein kinase assay and its application to the estimation of inhibitors because this method does not entail experimentally troublesome procedures such as the preparation of antibody or fluorescence-labeled substrate.

Chromatography, Micellar Electrokinetic Capillary↗

Determination of urinary hippuric acid by micellar electrokinetic capillary chromatography.

We propose a method for the simultaneous determination of hippuric acid (HA) and creatinine based on capillary micellar electrokinetic chromatography. Experimental conditions were 20 mM sodium phosphate, pH 7.20, 25 mM sodium dodecyl sulfate, 5% (v/v) acetonitrile. Electropherograms evidenced HA and creatinine peaks in less than 12 min. The method showed good linearity for both analytes and satisfactory within-day precision. The present method, which is accurate, sensitive, rapid and simple, may be applied to single-spot urine samples.

Chromatography, Micellar Electrokinetic Capillary↗

Quantitative structure-property relationship studies of migration index in microemulsion electrokinetic chromatography using artificial neural network.

Artificial neural networks (ANNs) were successfully developed for the modeling and prediction of migration indices of the 53 benzene derivatives and heterocyclic compounds in microemulsion electrokinetic chromatography. The selected descriptors that appear in multiple linear regression models are: 3D-MoRSE signal 25 unweighted, 3D-MoRSE signal 19 weighted by atomic Sanderson electronegativity, R maximal autocorrelation index lag 1 weighted by atomic mass (R1M+), R maximal autocorrelation index lag 2 weighted by polarizability (R2P+) and average atomic composition index. These descriptors were used as inputs for generated 5-4-1 networks. After training and optimization of the ANN parameters it was used to prediction of migration index of the test set compounds. The results obtained using ANNs were compared with the experimental values as well as with those obtained using regression models and showed the superiority of ANNs over regression models.

Chromatography, Micellar Electrokinetic Capillary↗