PubMed Health⌕ Search

PubMed · 12689112

Stochastic population dynamics: the Poisson approximation.

Abstract

We introduce an approximation to stochastic population dynamics based on almost independent Poisson processes whose parameters obey a set of coupled ordinary differential equations. The approximation applies to systems that evolve in terms of events such as death, birth, contagion, emission, absorption, etc., and we assume that the event-rates satisfy a generalized mass-action law. The dynamics of the populations is then the result of the projection from the space of events into the space of populations that determine the state of the system (phase space). The properties of the Poisson approximation are studied in detail. Especially, error bounds for the moment generating function and the generating function receive particular attention. The deterministic approximation for the population fractions and the Langevin-type approximation for the fluctuations around the mean value are recovered within the framework of the Poisson approximation as particular limit cases. However, the proposed framework allows to treat other limit cases and general situations with small populations that lie outside the scope of the standard approaches. The Poisson approximation can be viewed as a general (numerical) integration scheme for this family of problems in population dynamics.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hernán G Solari, Mario A Natiello. 2003-03-26. Stochastic population dynamics: the Poisson approximation.. https://doi.org/10.1103/physreve.67.031918

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

RadiSeq: a single- and bulk-cell whole-genome DNA sequencing simulator for radiation-damaged cell models.

Objective.To build and validate a simulation framework to perform single-cell and bulk-cell whole genome sequencing simulation of radiation-exposed Monte Carlo (MC) cell models to assist radiation genomics studies.Approach.Sequencing the genomes of radiation-damaged cells can provide useful insight into radiation action for radiobiology research. However, carrying out post-irradiation sequencing experiments can often be challenging, expensive, and time-consuming. Although computational simulations have the potential to provide solutions to these experimental challenges, and aid in designing optimal experiments, the absence of tools currently limits such application. MC toolkits exist to simulate radiation exposures of cell models but there are no tools to simulate single- and bulk-cell sequencing of cell models containing radiation-damaged DNA. Therefore, we aimed to develop a MC simulation framework to address this gap by designing a tool capable of simulating sequencing processes for radiation-damaged cells. Main results.We developed RadiSeq-a multi-threaded whole-genome DNA sequencing simulator written in C++. RadiSeq can be used to simulate Illumina sequencing of radiation-damaged cell models produced by MC simulations. RadiSeq has been validated through comparative analysis, where simulated data were matched against experimentally obtained data, demonstrating reasonable agreement between the two. Additionally, it comes with numerous features designed to closely resemble actual whole-genome sequencing. RadiSeq is also highly customizable with a single input parameter file.Significance.RadiSeq enables the research community to perform complex simulations of radiation-exposed DNA sequencing, supporting the optimization, planning, and validation of costly and time-intensive radiation biology experiments. This framework provides a powerful tool for advancing radiation genomics research.

Monte Carlo Method↗

[Method of calculating side scatter factor for diagnostic X-rays].

When computing the amount of leakage from a diagnostic X-ray room, the amount of scattered radiation released from the irradiated body in the lateral direction must be evaluated correctly. The side-scatter factor varies owing to change in the area and/or shape of the field, but the amount of variation is not always linearly proportional to the area of the field. Because the X-ray spectrum depends on the total filtration of the X-ray tube even if the irradiation geometry, X-ray equipment, and tube potential are the same, the side-scatter factor, too, is subject to change. In this paper, we propose a new method of calculation that uses the differential side-scatter factor computed by means of a Monte Carlo simulation, for obtaining the side-scatter factor of diagnostic X-rays. This method, which can calculate the side-scatter factor under any conditions of irradiation, is useful in evaluating the side-scatter factor of diagnostic X-rays.

Monte Carlo Method↗

Photoneutron yields from tungsten in the energy range of the giant dipole resonance.

Photoneutron production on the nuclei of high-Z components of medical accelerator heads can lead to a significant secondary dose during a course of bremsstrahlung radiotherapy. However, a quantitative evaluation of secondary neutron dose requires improved data on the photoreaction yields. These have been measured as a function of photon energy, neutron energy and neutron angle for natW, using tagged photons at the MAX-Lab photonuclear facility in Sweden. This work presents neutron yields for natW(gamma, n) and compares these with the predictions of the Monte Carlo code MCNP-GN, developed specifically to simulate photoneutron production at medical accelerators.

Monte Carlo Method↗