Abstract

The extension of microfluidic devices to include three-dimensional fluidic networks allows complex fluidic and chemical manipulations but requires innovative methods to interface fluidic layers. Externally controllable interconnects, employing nuclear track-etched polycarbonate membranes containing nanometer-diameter capillaries, are described that produce hybrid three-dimensional fluidic architectures. Controllable nanofluidic transfer is achieved by controlling applied bias, polarity, and density of the immobile nanopore surface charge and the impedance of the nanocapillary array relative to the microfluidic channels. Analyte transport between vertically separated microchannels has three stable transfer levels, corresponding to zero, reverse, and forward bias. The transfer can even depend on the properties of the analyte being transferred such as the molecular size, illustrating the flexible character of the analyte transfer. In a specific analysis implementation, nanochannel array gating is applied to capillary electrophoresis separations, allowing selected separated components to be isolated for further manipulation, thereby opening the way for preparative separations at attomole analyte mass levels.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tzu-Chi Kuo, Donald M Cannon, Yanning Chen, Joseph J Tulock, Mark A Shannon, Jonathan V Sweedler, Paul W Bohn. 2003-04-15. Gateable nanofluidic interconnects for multilayered microfluidic separation systems.. https://doi.org/10.1021/ac025958m

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A novel relationship between time offsets in capillary electrophoresis and DNA sequence variations in short tandem repeats.

Next-generation sequencing (NGS) provides increased discriminatory power in forensic DNA analysis due to the detection of isoalleles. Differences in sequences between alleles allow for a second layer of differentiation between DNA contributors beyond the number of short tandem repeat (STR) repeat units. However, because NGS is a more time and resource-intensive analysis than conventional capillary electrophoresis (CE), laboratories may benefit from indicators that suggest NGS is likely to provide added value. This study examined whether CE migration offsets, measured as residuals in the OSIRIS analysis software, can differ significantly among STR isoalleles. Residuals represent the time offset between a sample allele peak and its corresponding allelic ladder peak. Paired CE and NGS data from 95 single source samples were analyzed for CE-based residual differences, as the NGS data provided the sequence information of the corresponding isoalleles. Residual values differed significantly among isoalleles at several STR loci. Statistically significant differences were identified at D16S539 and D3S1358, as well as at specific allele lengths within D12S391, D13S317, and D8S1179. These findings demonstrate that CE residual variation can reflect underlying STR sequence differences between contributors. In practice, residual-based metrics could help laboratories to identify casework reference samples where NGS is likely to provide additional discrimination, without the need for processing outside of a routine CE workflow. Due to the potentially large number of isoalleles, community wide efforts to aggregate CE residual differences versus isoallele sequences may be useful in the validation and implementation of this approach to add value to forensic DNA analyses.

Electrophoresis, Capillary↗

Determination of urinary succinylacetone by capillary electrophoresis for the diagnosis of tyrosinemia type I.

The presence of succinylacetone in urine or blood or amniotic fluid is pathognomonic of an inherited metabolic disorder, named tyrosinemia type I. We developed a capillary electrophoretic method for the fast analysis of succinylacetone in urine samples. The separation was performed at reversed polarity mode using either a cationic surfactant as the buffer additive, or a capillary coated with a positively charged polyelectrolyte. Under these conditions, urine samples were directly injected to the capillary without any pretreatment step. The utility of the method was demonstrated by the identification of succinyacetone in urine from patients with hereditary tyrosinemia type I. For all patients, diagnostic peaks at the expected migration times were detected. The developed method is rapid, simple, inexpensive, and suitable for the determination of succinylacetone in clinical urine samples.

Electrophoresis, Capillary↗

Oligomerized phospholipid bilayers as semipermanent coatings in capillary electrophoresis.

Double-chained surfactants form semipermanent coatings that prevent protein adsorption in capillary electrophoresis (CE). To make such coatings more permanent, vesicles of the unsaturated phospholipid 1,2-dioleoyl-sn-glycero-3-phosphocholine were prepared and subjected to free-radical-initiated polymerization, both inside the capillary and in free solution. The latter generated oligomers of 2-5 units based on ESI-TOF MS, and formed the more stable coating in CE. Rinsing the capillary with a solution of the ex situ oligomerized DOPC suppressed EOF (0.8 x 10(-)(8) m(2)/V.s) for more than 20 h, whereas in situ oligomerized electroosmotic flow (EOF) suppressed the EOF for only 10 h. Mixtures of anionic and cationic proteins were separated under neutral pH and low ionic strength buffer with efficiencies of 480,000-930,000 plates/m and recoveries of 75-99%.

Electrophoresis, Capillary↗