PubMed Health⌕ Search

PubMed · 12718927

High-throughput protein crystallization.

Abstract

High-throughput structural biology is a focus of a number of academic and pharmaceutical laboratories around the world. The use of X-ray crystallography in these efforts is critically dependent on high-throughput protein crystallization. The application of current protocols yields crystal leads for approximately 30% of the input proteins and well-diffracting crystals for a smaller fraction. Increasing the success rate will require a multidisciplinary approach that must invoke techniques from molecular biology, protein biochemistry, biophysics, artificial intelligence, and automation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Raymond Hui, Aled Edwards. 2003. High-throughput protein crystallization.. https://doi.org/10.1016/s1047-8477(03)00046-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Automated identification of RNA conformational motifs: theory and application to the HM LSU 23S rRNA.

We develop novel methods for recognizing and cataloging conformational states of RNA, and for discovering statistical rules governing those states. We focus on the conformation of the large ribosomal subunit from Haloarcula marismortui. The two approaches described here involve torsion matching and binning. Torsion matching is a pattern-recognition code which finds structural repetitions. Binning is a classification technique based on distributional models of the data. In comparing the results of the two methods we have tested the hypothesis that the conformation of a very large complex RNA molecule can be described accurately by a limited number of discrete conformational states. We identify and eliminate extraneous and redundant information without losing accuracy. We conclude, as expected, that four of the torsion angles contain the overwhelming bulk of the structural information. That information is not significantly compromised by binning the continuous torsional information into a limited number of discrete values. The correspondence between torsion matching and binning is 99% (per residue). Binning, however, does have several advantages. In particular, we demonstrate that the conformation of a large complex RNA molecule can be represented by a small alphabet. In addition, the binning method lends itself to a natural graphical representation using trees.

Automation↗

Automated analysis of multiple sections for the detection of occult cells in lymph nodes.

PURPOSE: At present, reverse transcription (RT)-PCR against carcino-embryonic antigen mRNA is one of the few research tools for the detection of occult cells in histopathologically assessed negative lymph nodes from patients with colorectal cancer. The aim of this study was to investigate the suitability of supervised low-resolution image analysis of immunohistochemically stained sections as alternative. EXPERIMENTAL DESIGN: Multiple sections (n = 50) of regional lymph nodes from patients with colorectal cancer were immunohistochemically stained and analyzed by applying low-resolution image analysis (flatbed scanning) for semiautomated detection of cytokeratin (CK)-positive stained cells. The sensitivity of this approach was demonstrated for 20 patients with stage II colorectal cancer and compared with RT-PCR regarding the detection of clinically assessed recurrence of disease within 10 years. RESULTS: CK(+) cells were detected in all of the patients (n = 6; 100%) with recurrence, compared with five patients (83%) found positive by carcinoembryonic antigen RT-PCR. From patients (n = 14) who did not develop a recurrence, eight (57%) had positive lymph nodes. In all patients with recurrence, we visually identified at least one group of CK(+) cells (>/==" BORDER="0">2 cells). CONCLUSIONS: Automated image analysis is a promising tool for the detection of occult cells in histopathologically negative nodes. It is potentially more sensitive but less specific for detecting recurrence of disease than conventional histopathology or RT-PCR and is particularly useful for the evaluation of sentinel nodes. Furthermore, it opens new ways for basic research of occult cells based on molecular profiling after laser-microdissection.

Automation↗

Automated method for determination of glutardialdehyde residues in flexible endoscopes after disinfection.

Glutardialdehyde (GDA) is the most commonly used disinfectant for flexible endoscopes. After inappropriate rinsing of endoscopes residual GDA in the narrow endoscope channels may lead to toxic effects in patients. Common methods for determination of aldehydes in water involve derivatization with 2,4-dinitrophenylhydrazine (DNPH), liquid-liquid or solid-phase extraction and HPLC determination. Since derivatization and extraction is both time-consuming and labor-intensive only a small number of samples can be measured. Thus, we developed a fully automated method which includes a conventional HPLC system, a programmable autosampler, and UV detection. After GDA derivatization using DNPH the samples remain in the aqueous phase and no preconcentration of the analyte is necessary. The samples are automatically derivatized through the autosampler. While derivatization in one sample takes place the previous sample is injected and measured by HPLC. Our method is well suited for screening residual GDA in endoscopes as it is both time- and labor-saving.

Automation↗