PubMed Health⌕ Search

PubMed · 12723051

Membrane current from transmembrane potentials in complex core-conductor models.

Abstract

Core-conductor models, used to integrate the behavior of the longitudinal currents with the distributed voltages of electrically active tissue, have evolved for over a century. A critical step in the use of such models is the computation of membrane current from the set of distributed transmembrane potential values that exist at a given moment, where the potentials are obtained either experimentally or computationally. Over time, interest has developed in a number of substantial extensions of the original model to include such features as nonuniform spatial resistances, loop instead of linear structure, and multiple sites of extracellular stimulation. This paper concisely restates and extends the equations for calculation of transmembrane currents with the systematic inclusion of alternative cases, noting how they reduce to the standard forms. An important issue is how complex the calculation of membrane current has to be. Thus, the paper goes on to show criteria (based on the uniformity of resistance and the presence of stimulation) for deciding when membrane currents can be obtained with a relatively simple calculation with a single equation involving local variables versus with a more complex calculation involving the simultaneous solution of a (possibly large) set of equations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roger C Barr, Robert Plonsey, Chad R Johnson. 2003. Membrane current from transmembrane potentials in complex core-conductor models.. https://doi.org/10.1109/tbme.2003.809508

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of the location and magnitude of synaptic conductance changes in spinal motoneurons by impedance measurements.

The relation between impedance change and the location and magnitude of a tonic synaptic conductance was examined in compartmental motoneuron models based on previously published data. The dependency of motoneuron impedance on system time constant (tau), electrotonic length (L), and dendritic-to-somatic conductance ratio (rho) was examined, showing that the relation between impedance phase and rho differed markedly between models with uniform and nonuniform membrane resistivity. Dendritic synaptic conductances decreased impedance magnitude at low frequencies; at higher frequencies, impedance magnitude increased. The frequency at which the change in impedance magnitude reversed from a decrease to an increase-the reversal frequency, F(r)-was a good estimator of electrotonic synaptic location. A measure of the average normalized impedance change at frequencies less than F(r), cuDeltaZ, estimated relative synaptic conductance. F(r) and cuDeltaZ provided useful estimates of synaptic location and conductance in models with nonuniform (step, sigmoidal) and uniform membrane resistivity. F(r) also provided good estimates of spatial synaptic location on the equivalent cable in both step and sigmoidal models. Variability in relations between F(r), cuDeltaZ, and conductance location and magnitude between neurons was reduced by normalization with rho and tau. The effects on F(r) and cuDeltaZ of noise in experimental recordings, different synaptic distributions, and voltage-dependent conductances were also assessed. This study indicates that location and conductance of tonic dendritic conductances can be estimated from F(r), cuDeltaZ, and basic electrotonic motoneuron parameters with the exercise of suitable precautions.

Electric Impedance↗

Estimation of the size of air emboli detectable by electrical impedance measurement.

Non-invasive detection of air emboli in blood is investigated in vitro using a tetrapolar electrical impedance measurement. A cubic tank with a linear array of four electrodes, spaced approximately 1 cm apart down one side, was filled with 0.2 Sm(-1) saline. Bubbles were generated by carbon dioxide gas. Electrical transfer impedance was measured every 8.2 ms at 1.25 MHz. The movement of bubbles was recorded by a video camera, and their sizes and depths from the middle of the array were measured using captured video images. Changes in transfer impedance caused by passage of bubbles were clearly observed and almost identical with those calculated theoretically. Using lead field theory and experimental results, the fundamental limit on the detectable size of bubbles was estimated at the carotid artery, the great saphenous vein and the cephalic vein. The theoretical results showed that a 0.5 mm diameter bubble is detectable at a depth of 5.3 mm, similar to the depth of the great saphenous and the cephalic veins, and a 2.3 mm diameter bubble is detectable at a depth of 21 mm, similar to the depth of the common carotid artery.

Electric Impedance↗