PubMed Health⌕ Search

PubMed · 12723051

Membrane current from transmembrane potentials in complex core-conductor models.

Abstract

Core-conductor models, used to integrate the behavior of the longitudinal currents with the distributed voltages of electrically active tissue, have evolved for over a century. A critical step in the use of such models is the computation of membrane current from the set of distributed transmembrane potential values that exist at a given moment, where the potentials are obtained either experimentally or computationally. Over time, interest has developed in a number of substantial extensions of the original model to include such features as nonuniform spatial resistances, loop instead of linear structure, and multiple sites of extracellular stimulation. This paper concisely restates and extends the equations for calculation of transmembrane currents with the systematic inclusion of alternative cases, noting how they reduce to the standard forms. An important issue is how complex the calculation of membrane current has to be. Thus, the paper goes on to show criteria (based on the uniformity of resistance and the presence of stimulation) for deciding when membrane currents can be obtained with a relatively simple calculation with a single equation involving local variables versus with a more complex calculation involving the simultaneous solution of a (possibly large) set of equations.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roger C Barr, Robert Plonsey, Chad R Johnson. 2003. Membrane current from transmembrane potentials in complex core-conductor models.. https://doi.org/10.1109/tbme.2003.809508

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Use of multichannel intraluminal impedance to document proximal esophageal and pharyngeal nonacidic reflux episodes.

Recent studies in adults and children suggest that combined multichannel intraluminal impedance and pH measurement (MII-pH) has the potential to become the new "gold standard" for gastroesophageal reflux testing. In combined MII-pH, reflux is detected by changes in resistance to alternating current induced by the presence of intraluminal materials with different conductivities, and is characterized as acid or nonacid reflux based on concomitant pH measurements. Proximal distribution and duration of nonacid reflux events, predominantly in postprandial periods and during acid-suppressive therapy, can now be quantified. The ability to associate symptoms with nonacid reflux events will help guide therapy in select groups of patients, such as patients with ongoing symptoms on acid-suppressive therapy as well as in the pediatric population.

Electric Impedance↗

Simultaneous determination of the size and surface charge of individual nanoparticles using a carbon nanotube-based Coulter counter.

A resistive-pulse Coulter counter based on a membrane containing a single multiwall carbon nanotube (MWNT) channel was used to simultaneously determine the size and surface charge of carboxy-terminated polystyrene nanoparticles. The membrane was prepared from an epoxy section containing a MWNT channel mounted on a poly(dimethylsiloxane) (PDMS) support structure. The PDMS support reduced the background noise level by a factor of > 20 compared to the Si/Si3N4 support structure used in our previous study. The lower noise level makes it possible to accurately measure the height and width of resistive-pulse signals resulting from transport of individual particles through the MWNT channel. Particle sizes, calculated from current pulse heights, were comparable to those determined by transmission electron microscope (TEM). The width of the current pulses is a measure of the nanoparticle transport time, and it permits calculation of the electrokinetic surface charge. Different types of polystyrene nanoparticles having nearly the same size, but different electrokinetic surface charge, could be resolved on the basis of the difference in their transport time.

Electric Impedance↗

The effect of ohmic heating on vacuum drying rate of sweet potato tissue.

Ohmically heating fruit and vegetable tissue has been shown to increase hot-air drying rate, shift desorption isotherms, and increase juice extraction yields with respect to untreated, conventionally heated, and microwaved samples. The objective of this study was to determine if ohmically heating sweet potato tissue would enhance the vacuum drying rate of these samples with respect to untreated samples. Sweet potato cubes were ohmically heated to three endpoint temperatures using three electrical field strengths and were then placed in a freeze dryer. Moisture content vs. time data were collected and modeled. Results showed that the vacuum drying rates of ohmically heated samples were faster than raw samples for most treatment combinations, and that the maximum reduction of drying time was 24%. Minimal ohmic treatment can result in a significant decrease in vacuum drying time, which could have important economic and product quality implications.

Electric Impedance↗