Replacing mercury-column sphygmomanometers.

Abstract

Mercury-based devices have a long history of use in the healthcare setting. However, mercury poses a significant occupational and environmental exposure hazard. In recognition of this hazard, the American Hospital Association and the U.S. Environmental Protection Agency have set a goal to eliminate mercury in healthcare by 2005. As a result, healthcare facilities are now under increasing pressure to replace mercury-based equipment. Thermometers and sphygmomanometer columns are the most prevalent sources of metallic mercury in the healthcare setting. Many hospitals have already swapped mercury thermometers for electronic devices. Replacing mercury sphygmomanometers, however, has been more problematic, as concerns have been raised about the accuracy of the alternatives. Despite these concerns, some hospitals have been able to eliminate or significantly reduce the presence of mercury sphygmomanometers. In this Guidance Article, we describe factors that healthcare facilities should consider when choosing from among the available blood pressure measurement methods, and we provide practical advice for facilities trying to make the switch from mercury sphygmomanometers to alternative methods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

2003. Replacing mercury-column sphygmomanometers.. https://pubmed.ncbi.nlm.nih.gov/12751146/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tip cooling effect and failure mechanism of field-emitting carbon nanotubes.

The cooling effect accompanying field electron emission has been considered for a single carbon nanotube (CNT) used as a field emission (FE) electron source. An improved model for the failure mechanism of field emitting CNTs has been proposed and validated. Our model predicts a maximum temperature (T-max) located at an interior point rather than the tip of the CNTs, and the failure of the CNT emitters tends to take place at the T-max point, inducing a segment by segment breakdown process. A combination of Joule heating and electrostatic force effect is proposed responsible for initiating the failure of the field emitting CNT and validated by in situ FE observation.

Equipment Failure↗

[Importance of an initial check-up for diagnostic radiology apparatus management].

The management of apparatus for diagnostic imaging is an important job for radiological technologists. In the last 10 years we have encountered 2227 malfunctions in 3652 days. We detected 163 cases at the initial check-up, which accounted for 7.3% of total cases. By performing an initial check-up, we detected one malfunction every 21 days and were able to keep the effects of mishaps to a minimum, prevent accidents, and obtain stable-quality images.

Equipment Failure↗