PubMed Health⌕ Search

PubMed · 12775666

Randomized controlled trial of a computer-assisted learning program to improve caries detection from bitewing radiographs.

Abstract

OBJECTIVES: To investigate whether using a computer-assisted learning (CAL) calibration program improves the accuracy of dental students in caries detection from bitewing radiographs. METHODS: Dental students were assigned to an experimental (n=33) and control (n=34) group using a randomized block design. The experimental group used the CAL program with feedback to calibrate themselves against experts in radiographic caries detection and a histological gold standard of the actual clinical condition. Feedback was provided visually of the actual tooth surface condition and in the form of graphics showing diagnostic accuracy performance measures. Performance was tested before the program (for the control group) and after the program (for the experimental group) by assessing surfaces (n=56) from a new independent digital test set of evaluation radiographs for the presence, histologically, of dentine caries (n=23). The summary receiver operating characteristic (SROC) method for summarizing true positive ratio (TPR) (sensitivity) and false positive ratio (FPR) (1-specificity) was used to analyse the dichotomous data. Differences between the control and experimental groups were tested for (a) the area under the SROC curve (A(z)) and (b) the TPR, FPR and diagnostic odds ratio (DOR) using the Mann-Whitney test (P<0.05). RESULTS: The mean TPR for dentine caries detection was 76.3% (SD 13.0%) for the experimental group and 66.9% (SD 14.8%) for the control group (P=0.005). Mean FPRs were similar (experimental 28.1% and control 28.7%; P>0.5). The area under the SROC curve A(z) was 0.832 for the experimental group and 0.773 for the control group (P=0.002). The mean DOR for dentine caries in the experimental group (12.4) was better than that in the control group (8.8) (P=0.003). CONCLUSIONS: The CAL program does improve diagnostic performance. Improving the cognitive feedback provided by the program should be considered before implementation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P A Mileman, W B van den Hout, G C H Sanderink. 2003. Randomized controlled trial of a computer-assisted learning program to improve caries detection from bitewing radiographs.. https://doi.org/10.1259/dmfr%2F58225203

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Smooth semiparametric receiver operating characteristic curves for continuous diagnostic tests.

We propose a semiparametric kernel distribution function estimator, based on which a new smooth semiparametric estimator of the receiver operating characteristic (ROC) curve is constructed. We derive the asymptotic bias and variance of the newly proposed distribution function estimator and show that it is more efficient than the traditional non-parametric kernel distribution estimator. We also derive the asymptotic bias and variance of our new ROC curve estimator and show that it is more efficient than the smooth non-parametric ROC curve estimator proposed by Zou et al. (Stat. Med. 1997; 16:2143-2156) and Lloyd (J. Am. Stat. Assoc. 1998; 93:1356-1364). For our proposed estimators, we derive data-based methods for bandwidth selection. In addition, we present some results on the analysis of two real data sets. Finally, a simulation study is presented to show that our estimators are better than the non-parametric counterparts in terms of bias, standard error, and mean-square error.

Area Under Curve↗

Redox potential measurement as a rapid method for microbiological testing and its validation for coliform determination.

The redox potential is one of the most complex indicators of the physiological state of microbial cultures and its measurement could be a useful tool for the qualitative and quantitative determination of the microbial contamination. During the bacterial growth, the redox potential of the medium decreases. The shape of the redox potential curve is characteristic on the type of microorganism, and the rate of the change (dE/dt) is proportional to the living cell concentration. Defining the time required to reach a significant change in redox potential as Time to Detection (TTD), similarly to the impedimetric measurements, a strict linear correlation could be established between the TTD and the logarithm of the initial concentration of microorganisms. On the base of this calibration curve, the determination of living cell concentration could be simplified. For the experiments, a computer-controlled multi-channel measuring system and software was developed by the authors. The redox potential measurement method was tested and validated for the determination of coliform bacteria. The results have proved the high efficiency and reliability of the new method.

Area Under Curve↗

Determination of N-methyl-4-isoleucine-cyclosporin (NIM811) in human whole blood by high performance liquid chromatography-tandem mass spectrometry.

A liquid chromatographic method with tandem mass spectrometric detection (LC-MS/MS) for the determination of N-methyl-4-isoleucine-cyclosporin (NIM811) was developed and validated over the concentration range 1-2500 ng/mL in human whole blood using a 0.05 mL sample volume. NIM811 and the internal standard, d(12)-cyclosporin A (d(12)-CsA), were extracted from blood using MTBE via liquid-liquid extraction. After evaporation of the organic solvent and reconstitution, a 10 microL aliquot of the resulting extract was injected onto the LC-MS/MS system. Chromatographic separation of NIM811 and internal standard was performed using a Waters Symmetry RP-8 (50 x 4.6 mm, 3 microm particle size) column. The mobile phase consists of 10 mm ammonium acetate in water (A) and acetonitrile (B), with 45% B from 0 to 0.2 min, 45 to 85% B from 0.2 to 0.8 min and 85% B from 0.8 to 2.2 min. The total run time was 3.5 min with a flow rate of 0.8 mL/min. The method was validated for sensitivity, linearity, reproducibility, stability, dilution integrity and recovery. The precision and accuracy of quality control samples at low (2.00 ng/mL), medium (20.0 and 400 ng/mL) and high (2000 ng/mL) concentrations were in the range 1.1-4.3% relative standard deviation (RSD) and -2.5-10.0% (bias), respectively, from three validation runs. The method has been used to measure the exposure of NIM811 in human subjects.

Area Under Curve↗