PubMed Health⌕ Search

PubMed · 12792473

Corneal topography and accommodation.

Abstract

PURPOSE: To investigate whether there are significant changes in corneal topography during accommodation in normal corneas and corneas that are pathologically thinner due to keratoconus. METHODS: A videokeratoscope was modified to present an accommodation stimulus that was coaxial with the instrument's measurement axis. Six subjects with normal corneas and four subjects with keratoconus were studied. Eighteen videokeratoscope measurements of one eye of each subject were taken at 0 diopter (D) accommodation demand and six for both of 4 D and 9 D accommodation demand. The effects of ocular micromovements on multiple topography maps were minimized using software algorithms. Average maps for the 4 D and 9 D accommodation demands were calculated and subtracted from the average map of the 0-D accommodation demand. A t test was applied at each point location within the topography maps to analyze the statistical significance of change (p < 0.001) within the difference maps. RESULTS: In the initial analysis, we found that a number of the subjects showed significant changes in corneal topography as accommodation changed. However, further analysis showed a significant group mean excyclotorsion of the topography maps of 1.6 +/- 1.1 degrees (p < 0.03) for the 4-D stimulus and 2.0 +/- 1.3 degrees (p < 0.01) for the 9-D stimulus compared with the 0-D stimulus. When we accounted for the excyclotorsion, we did not find clear evidence of statistically significant changes in corneal topography as a result of accommodation, either for the normal corneas or the keratoconic corneas. CONCLUSIONS: It appears unlikely that changes occur in central corneal shape during accommodation up to a level of 9 D in normal or keratoconic corneas. A small ocular excyclotorsion typically accompanies accommodation, and this changes the relative orientation of the topography of the cornea. This has significant implications for the interpretation of the optical characteristics of eyes during near viewing conditions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tobias Buehren, Michael J Collins, Jim Loughridge, Leo G Carney, D Robert Iskander. 2003. Corneal topography and accommodation.. https://doi.org/10.1097/00003226-200305000-00007

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Conceptual model of human blur perception.

An empirically based, conceptual model of human blur perception is presented. It incorporates the concepts of blur detection and blur discrimination in depth, and across the central and peripheral retina, in two- and three-dimensional visual space. Key aspects of the model are its dynamic nature, predictability regarding the blur-based depth-ordering of objects, patterns of retinal defocus with far and near viewing, and interactions related to retinal defocus between the central and peripheral retina. Furthermore, a two-dimensional schematic representation of the blur-free region during near viewing is depicted in dioptric space. This model has implications with respect to accommodative control, depth perception, and refractive error development and progression.

Accommodation, Ocular↗

The effect of human in vivo accommodation on crystalline lens stability.

AIM: To determine the effect of human in vivo accommodation on the stability of the crystalline lens. METHODS: Using a dual Purkinje image (DPI) eyetracker, the phase-time difference and amplitudes of Purkinje images I (P(I)) and IV (P(1V)) were measured in 37 normal emmetropic subjects (34 women and 3 men; mean age 19.8, range 18-22 years) when they changed focus from 70 to 15 cm and simultaneously rotated their heads horizontally from side to side or made horizontal saccades between two targets 6.8 degrees apart. RESULTS: When the subjects changed focus from 70 to 15 cm and rotated their heads or made eye saccades, the phase-time difference between P(I) and P(IV) decreased. During saccades, the amplitude of both P(I) and P(IV) overshoots significantly increased with focus at 15 cm; however, their ratio (P(IV) overshoot amplitude/P(I) overshoot amplitude) significantly declined. CONCLUSIONS: The lens is stable during accommodation. The implications of these findings on the mechanism of accommodation are discussed.

Accommodation, Ocular↗

Synchrony dual-optic accommodating intraocular lens. Part 2: pilot clinical evaluation.

PURPOSE: To evaluate the clinical outcomes of an accommodating dual-optic intraocular lens (IOL). SETTING: Private practice and university centers. METHODS: A prospective noncomparative case series with retrospective control comprised 21 patients (26 eyes) scheduled for small-incision extracapsular cataract extraction by phacoemulsification with implantation of the Synchrony dual-optic accommodating IOL (Visiogen) (accommodating IOL group) and 10 patients who had small-incision extracapsular phacoemulsification with implantation of a monofocal, single-optic IOL at least 6 months previously (control group). Patients were examined 1, 3, 6, and 12 months after surgery. Defocus curves in the accommodating IOL group were compared with those in the control group. The main outcome measures were postoperative distance uncorrected and best corrected visual acuity; near uncorrected, distance corrected, and near corrected visual acuity; and accommodative range based on defocus curves. RESULTS: Twenty-four eyes were available at the 6-month follow-up visit. All eyes had best corrected distance visual acuity of 20/40 or better, and 19 eyes (79%) had an uncorrected distance visual acuity of 20/40 or better. Uncorrected near visual acuity was 20/40 or better in all eyes. With distance correction, 23 eyes (96%) had an acuity of 20/40 or better at near. Defocus curve analysis suggested a mean accommodative range of 3.22 diopters (D) +/- 0.88 (SD) (range 1.00 to 5.00 D) in the accommodating IOL group and 1.65 +/- 0.58 D in the control group (range 1.00 to 2.50 D) (P<.05). CONCLUSION: The Synchrony dual-optic IOL shows promise as an option to provide accommodative function in pseudophakic patients.

Accommodation, Ocular↗