PubMed Health⌕ Search

PubMed · 12797337

Using an ear thermometer.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Richard L Pullen. 2003. Using an ear thermometer.. https://doi.org/10.1097/00152193-200305000-00021

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Accuracy and stability of temperature probes for intracranial application.

Intracranial temperature measurement may play a pivotal role for prognosis and treatment of neurological and neurosurgical patients. For reliable clinical application, accurate temperature readings are therefore necessary. We present an independent in vitro study investigating the accuracy and stability of three temperature probes. Eight Neurovent-P Temp (RN), eight Licox temperature sensors (LT) and eight Neurotrend sensors (NT) were placed into a water bath. The temperature was increased in 3 degrees C increments from 30 to 42 degrees C before (accuracy test day 0) and after (accuracy test day 5) a long-term stability test run at 37 +/- 0.2 degrees C. The accuracy tests revealed deviations of <0.25, <0.2 and >0.4 degrees C for the RN, NT and LT probes, respectively, when compared to the reference measurement by a precision Pt100 temperature measuring instrument. All sensor types showed stable readings over the course of 120 h. The high variability of LT probes was due to a malfunctioning Licox monitor. Excluding these values reduced deviation below 0.21 degrees C the standard deviation at each temperature step was below +/-0.08 (RN, NT) and +/-0.12 (LT), laying within the range provided by the manufacturer (RN, NT: +/-0.1; LT: +/-0.2). In general, RN, NT and LT temperature measurement is reliable, but malfunctioning parts may lead to false interpretation of temperature readings. Therefore, validation of temperature probes to a reference temperature prior to clinical use is recommended.

Body Temperature↗

Model of local temperature changes in brain upon functional activation.

Experimental results for changes in brain temperature during functional activation show large variations. It is, therefore, desirable to develop a careful numerical model for such changes. Here, a three-dimensional model of temperature in the human head using the bioheat equation, which includes effects of metabolism, perfusion, and thermal conduction, is employed to examine potential temperature changes due to functional activation in brain. It is found that, depending on location in brain and corresponding baseline temperature relative to blood temperature, temperature may increase or decrease on activation and concomitant increases in perfusion and rate of metabolism. Changes in perfusion are generally seen to have a greater effect on temperature than are changes in metabolism, and hence active brain is predicted to approach blood temperature from its initial temperature. All calculated changes in temperature for reasonable physiological parameters have magnitudes <0.12 degrees C and are well within the range reported in recent experimental studies involving human subjects.

Body Temperature↗