PubMed Health⌕ Search

PubMed · 12824577

High-throughput screen for aromatic hydroxylation.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Christopher R Otey, John M Joern. 2003. High-throughput screen for aromatic hydroxylation.. https://doi.org/10.1385/1-59259-396-8%3A141

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of peroxides in saliva--kinetics of peroxide release into saliva during home-bleaching with Whitestrips and Vivastyle.

Aim of the study was to determine peroxides in saliva, released during bleaching procedures. Upper incisors of five subjects were bleached with Whitestrips (5% H2O2) and Vivastyle (10% carbamide peroxide, tray charged with 225mg) for 30min, each on different days. Saliva was collected before and during the whole period of bleaching at different intervals. The amount of peroxide in the salivary samples was assessed with peroxidase, phenol and 4-aminoantipyrin in a photometric assay. Additionally the amount of peroxides in the bleaching material was determined before and after the bleaching, so that the peroxide release into saliva could be balanced. The amount of peroxides released into saliva was related to the bleaching system and only partially influenced by the individual salivary flow rate. Bleaching with Vivastyle led to lower release of peroxides into saliva compared to Whitestrips (Vivastyle: 0.8+/-0.17mg; Whitestrips: 1.5+/-0.84mg). Salivary flow rate was not correlated to release of peroxides from the bleaching products. It can be concluded that the enzymatic method adopting 4-aminoantipyrin and peroxidase is valid for the determination of peroxides in saliva. Furthermore distinctly more peroxides are released into the oral cavity from Whitestrips than from trays charged with Vivastyle .

Ampyrone↗

Determination of polyphenols in wines by reaction with 4-aminoantipyrine and photometric flow-injection analysis.

A new flow-injection analytical procedure is proposed for the determination of the total amount of polyphenols in wines; the method is based on the formation of a colored complex between 4-aminoantipyrine and phenols, in the presence of an oxidizing reagent. The oxidizing agents hexacyanoferrate(III), peroxodisulfate, and tetroxoiodate(VII) were tested. Batch trials were first performed to select appropriate oxidizing agents, pH, and concentration ratios of reagents, on the basis of their effect on the stability of the colored complex. Conditions selected as a result of these trials were implemented in a flow-injection analytical system in which the influence of injection volume, flow rate, and reaction-coil length, was evaluated. Under the optimum conditions the total amount of polyphenols, expressed as gallic acid, could be determined within a concentration range of 36 to 544 mg L(-1), and with a sensitivity of 344 L mol(-1) cm(-1) and an RSD <1.1%. The reproducibility of analytical readings was indicative of standard deviations <2%. Interference from sugars, tartaric acid, ascorbic acid, methanol, ammonium sulfate, and potassium chloride was negligible. The proposed system was applied to the determination of total polyphenols in red wines, and enabled analysis of approximately 55 samples h(-1). Results were usually precise and accurate; the RSD was <3.9% and relative errors, by the Folin-Ciocalteu method, <5.1%.

Ampyrone↗

Kinetic flow-injection determination of hydrogen peroxide by use of iron(III)-catalyzed coloration and its application to the determination of biological substances.

A kinetic flow-injection (FI) method is described for the determination of hydrogen peroxide. This method is based on an iron(III)-catalyzed oxidative coupling of 4-aminoantipyrine with N,N-dimethylaniline by hydrogen peroxide. By measuring the change in the absorbance of the dye formed at 560 nm, 1 x 10(-6) - 6 x 10(-4) M hydrogen peroxide could be determined with a sampling rate of 15 h(-1). The relative standard deviation (n = 30) was 0.8% for 5 x 10(-5) M hydrogen peroxide. There was little interference of the co-existing ions and compounds. After introducing some immobilized enzyme reactors to the FI system, the proposed method allowed the determination of glucose and uric acid ranging from 1 x 10(-6) to 6 x 10(-4) M with relative standard deviations of below 2%. The applicability of the method was demonstrated by determining these substances in serum samples.

Ampyrone↗