PubMed Health⌕ Search

PubMed · 12851828

Error bands for the linear-quadratic dose-effect relation.

Abstract

Least square or maximum likelihood fits to the linear-quadratic dose-effect relation are common in experimental radiobiology and in radio-epidemiology. The fit procedure provides the estimates of the linear and the quadratic dose coefficients, a and b, as well as their standard errors, s(a) and s(b). The magnitude of the standard errors s(a) and s(b) is partly determined by the fact that-for a given data set-different parameter combinations (a, b) can produce rather similar fits, i.e. larger values of a can be roughly compensated by smaller values of b. The values s(a) and s(b) are, because of this interrelation, unsuitable to determine error bands of the dose-effect relation. The exact analysis accounts for the co-variance of the parameters, but it is rarely employed. To avoid the consideration of co-variances a simple parameter change is introduced here that replaces the dose-squared coefficient, b, by a+ bDelta. This term is the effect-to-dose ratio at the reference dose Delta, and can thus be termed reference slope. With the proper value of Delta-which is readily determined for a data set, and is 2 Gy for the dicentric chromosome data which are used as example-the two parameters initial slope, a, and reference slope are then orthogonal, i.e. there is no inter-dependence of the parameter values, and their uncertainties can be treated as independent. In the case of three-model parameters, e.g. the linear-quadratic model with an intercept term, c, the same type of parameter change can be applied to make both the first and the third parameter orthogonal to a. The curve fit is then performed conveniently with the standard computer routines, and parameter uncertainties are obtained that provide by simple error propagation the equations for the standard error or confidence bands of the dose-effect relation. Appendix A gives the numerical scheme.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A M Kellerer. 2003-07-08. Error bands for the linear-quadratic dose-effect relation.. https://doi.org/10.1007/s00411-003-0195-6

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Radiation tolerance of normal temporal bone structures: implications for gamma knife stereotactic radiosurgery.

Popular current thought states that hearing loss and facial weakness after radiosurgery of vestibular schwannomas is a function of cranial nerve damage. Although this may be true in some cases, the middle and inner ear contain rich networks of other sensitive structures that are at risk after radiotherapy and that may contribute to toxicity afterward. We reviewed the limited reported data regarding radiation tolerance of external, middle, and inner ear structures, and perspectives for therapy with gamma knife stereotactic radiosurgery are addressed.

Dose-Response Relationship, Radiation↗

The human visual threshold depends on direction and strength of a weak magnetic field.

Completing our investigations concerning influences of weak magnetic fields on the visual discrimination threshold, we have investigated 30 subjects (20 female, 10 male) under rotation of the geomagnetic field without change in field strength. We related the thresholds to the values measured in the unchanged field. Comparison with a control experiment shows that correspondence between viewing and field direction results in a significant decrease of the threshold. The significance is lost if the angle between the directions is set to 20 degrees. On the basis of these and our earlier results an attempt is made to give a very simple description of the connection between field direction, field strength, and the change in the visual discrimination threshold.

Dose-Response Relationship, Radiation↗

Intraspecific variation in retinal cone distribution in the bluefin killifish, Lucania goodei.

Studies of visual ecology have typically focused on differences among species while paying less attention to variation among populations and/or individuals. Here, we show that the relative abundance of UV, violet, yellow, and red cones varies between two populations of bluefin killifish, Lucania goodei. Animals from a spring population (high-transmission UV/blue light) have a higher frequency of UV and violet cones and a lower frequency of yellow and red cones than animals from a swamp population (low-transmission UV/blue light). Visual sensitivity does not vary significantly between the populations, but spring animals tend to be more sensitive in the UV/blue wavelengths (360-440 nm) and less sensitive in longer wavelengths (560-600 nm) than swamp animals. The results have two important implications. First, the tight conservation of functional regions of opsin genes across taxa does not imply that visual systems are constrained in their evolution; differential sensitivity can arise through differential expression of cone classes within the retina. Second, intraspecific visual signals in this species may evolve to maximize contrast between the signaler and the background (as opposed to brightness); males with blue anal fins are most abundant in swamp habitats where animals express fewer UV and violet cones.

Dose-Response Relationship, Radiation↗