Intraperitoneal pocket for left ventricular assist device placement.

Abstract

BACKGROUND: Implantation of the HeartMate Implanted Pneumatic or Vented Electric Ventricular Assist Device requires that the pump be implanted either in the peritoneal cavity or in the abdominal wall. Both sites have been problematic. METHODS: We describe a new technique in which an intraperitoneal pocket is created, using Gore-Tex Dual Mesh Plus Biomaterial with Holes, to contain the ventricular assist device. This shields the ventricular assist device from the peritoneal contents and avoids abdominal wall dissection. Thirty consecutive patients who underwent implantation using this technique were compared with 16 patients who underwent implantation before this technique was in use. RESULTS: Thirty consecutive patients underwent implantation, and 2 of those patients underwent re-implantation because of device failure (16/30 HeartMate Implanted Pneumatic, 14/30 HeartMate Vented Electric, and 2/14 HeartMate Vented Electric replaced with the HeartMate Implanted Pneumatic). Twenty-five patients have undergone explantation. Pocket infections in patients who have had implanted devices for >1 month decreased from 4 of 13 before the pockets were used to 1 of 25 with the intraperitoneal pockets (Fisher's exact test p = 0.038). Two hernia repairs were required after explantation when the biomaterial pocket was used. A decrease in return to surgery for bleeding was noted after the pocket was used (7/16 without the pocket and 3/32 with the pocket; Fisher's exact test, p = 0.010). CONCLUSIONS: Bleeding complications and pocket infections decreased in this early experience. Further study is necessary to confirm the apparent decrease in complication rate by using this new technique in this small cohort of patients.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tim Icenogle, David Sandler, Mark Puhlman, Steve Himley, David J Sato, Stacy Schaefer. 2003. Intraperitoneal pocket for left ventricular assist device placement.. https://doi.org/10.1016/s1053-2498(02)00644-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Corporeal excavation: new technique for penile prosthesis implantation in men with severe corporeal fibrosis.

INTRODUCTION: Penile prosthesis implantation in men who have fibrotic corpora as the result of ischemic priapism or previous removal of an infected penile prosthesis poses a significant challenge to the implanting surgeon. We describe a new technique, corporeal excavation, to meet this challenge. TECHNICAL CONSIDERATIONS: The operative approach is through an inverted T penoscrotal incision that affords exposure of nearly the entire corpus cavernosum on each side. Extended corporotomies are made on the ventral aspect of each corpus cavernosum, and a plane of dissection between the fibrotic corporeal tissue and the inner surface of the tunica albuginea is established, resulting in core removal of nearly all fibrotic intracorporeal tissue. Cylinders are laid into the empty corporeal bed, and the tunica albuginea is closed primarily. Nine patients were identified who had undergone this procedure. The operative notes and medical records were reviewed, and telephone interviews were done for follow-up when patients had not been recently seen in the clinic. CONCLUSIONS: Successful outcomes were achieved in all 9 patients. Corporeal excavation permits penile prosthesis implantation in men with severe intracorporeal fibrosis usually resulting from priapism or previous removal of infected penile prostheses.

Device Removal↗

Feasibility and outcomes of an early extubation policy after esophagectomy.

BACKGROUND: Although early extubation of esophagectomy patients has been found to be feasible, safe, and associated with low morbidity, there is no uniform standard of care among high volume centers. Our objective is to examine a contemporary series of esophagectomies and identify the feasibility and outcome of an early extubation policy. METHODS: This study is a retrospective review of all patients who underwent esophagectomy between January 2003 and December 2004 at the Massachusetts General Hospital. One hundred and two patients were analyzed from 129 consecutive patients who underwent esophagectomy and subsequently divided in two groups: The early extubation group was extubated in the operating room and the late extubation group was extubated in the intensive care unit (ICU). RESULTS: Ninety percent were extubated early. Although most patients underwent a transthoracic or thoracoabdominal esophagectomy, the operative approach did not influence failure to extubate. Neoadjuvant therapy was not predictive of extubation failure. Most patients age 70 or greater (86%) were extubated early. There were three nonelective reintubations in the early extubation group secondary to acute respiratory distress syndrome. The median length of stay was 11 days and median ICU stay was one day. The 30-day mortality was 1.9% and the median survival was 28 months. CONCLUSIONS: Attention to restricted intraoperative fluid balance, limited blood loss, anesthetic technique, and epidural use permit most patients undergoing esophageal resection to be safely extubated immediately postresection in the operating room.

Device Removal↗